Esat, helium and very low PPO2s - I am diving in the .8 range. -----Original Message----- From: Esat Atikkan [mailto:atikkan@ya*.co*] Sent: Monday, March 11, 2002 9:23 PM To: Bruce R. Wienke; deco@de*.or*; techdiver@aquanaut.com Subject: Re: FYI: RGBM WKPP/Irvine Test Deco Profile Comparison The issue is nothing but having the biochem run following dives. It would B best that it B run in the absence of DCS S&S as that would provide the baseline, & hopefully the abberation that leads to DCS would become evident. As for He, obviously good approach but still does not take peroxinitrates out of the picture as that lies in the cGMP/NO pathway that is thought to B central to the relaxation of vascular smooth muscle. There is no question that being in good cardiovascular & physical shape has benefits, but it is doubtful that it would afford protections against SOD depletion and/or peroxinitrates. Safe bubbles Esat Atikkan --- "Bruce R. Wienke" <brw@la*.go*> wrote: > Yes. > > Would be very interesting indeed -- this info > needs folding into > diving on the envelope. Especially considering the > stress. > > We take Vits. exercise, and are in great shape > here at/on > LANL D-team, and will soon wet test 400/30 with He > on way up (not > nitrox switches that George uses). Our dives are > almost 90% He > these days -- we avoid N2 as much as possible. We > are highly DCI absent > on RGBM schedules. Bottom line -- deep stops are > safe, cost effective, > and time saving. Even if "arbitrarily" built up > from Haldane. > > Can't accurately quantify such complex > biochemistry, vascularity > and related phenomenon, but such in coarse grain > deco planners enter thru > bub > distribution, perfusion dilatation, etc., and > possibly oxygen sat. If you > have data linked to DCI, we might be able to say > something? > > > BW > > > > >has anyone looked at hematological & bichemical > >parameters following these dives: > >Crit, [Hb], plasma osmolarity, RBC fragility come > to > >mind as do plasma volume changes. > > > >This would B fertile ground to assess the oxidative > >stress of such dives, wh/, over the long haul, may > B > >more significant than the putative bubble problems. > > > >I think Irvine & co deal w/ oxidative stress > through > >supplements of Vit E & C, wh/ would ameliorate the > SOD > >depletion, particularly the Cu/Zn SOD of the RBCs. > > > >However, the peroxinitrate relaxation mediated > >comprimise of vascular endothelial integrity does > come > >to mind as an area needing study. > > > >If I recollect correctly this was studied & > published > >(Undersea Hyperbar Med in the late 90's does come > to > >mind). how it applies to the dives modelled here > >would be of interest. > > > >Safe bubbles > > > >Esat Atikkan > > > >__________________________________________________ > >Do You Yahoo!? > >Try FREE Yahoo! Mail - the world's greatest free > email! > >http://mail.yahoo.com/ > > > __________________________________________________ Do You Yahoo!? Try FREE Yahoo! Mail - the world's greatest free email! http://mail.yahoo.com/ -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'. -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.
Navigate by Author:
[Previous]
[Next]
[Author Search Index]
Navigate by Subject:
[Previous]
[Next]
[Subject Search Index]
[Send Reply] [Send Message with New Topic]
[Search Selection] [Mailing List Home] [Home]