Mailing List Archive

Mailing List: techdiver

Banner Advert

Message Display

To: Christina_Young@Wa*.Me*.co*
Subject: Re: Poseidon Jetstreams (Odins)
From: Sten Meyer <m87stme@mt*.ch*.se*>
Cc: techdiver@opal.com
Cc: JOHNCREA@de*.co*
Date: Sat, 4 Feb 1995 15:59:59 +0100 (MET)
On Fri, 3 Feb 1995 Christina_Young@Wa*.Me*.co* wrote:

> 
> Sten,
> 
> Yes, I had thought about 1st stage reaction to pressure being drawn
> by the second stage.  That is why I stated, "pressure not to exceed
> 170 psi".  When the IP is set at 170 psi, for instance, on the Odin,
> does this mean that when pressure is drawn (resulting in an IP drop,
> recognized by the feedback loop of the 1st stage), the IP *exceeds*
> 170 psi???

I have not tested IP's in this range on my Jetstream first stage. But
the feedback was strong with the original HP-seat. I meassured some
2 bars boost of the IP messured at the suit infaltor when I pressed
the purge. At low flows (ie a slow inhalation) the pressure boost
was minimal. When I made these tests the IP was set at approx 9 bars.

During one period the hole from the "R" port to the membrane chamber
was machined so that a plastic insert could be fitted. This inset has
a 1 mm hole. With this insert the feedback was reduced and a Cyklon
second stage could be fitted to the "R" port, and work with the
right IP (12,5 bar)

(1 bar = 14.50... psi)

/Sten Meyer                   m87stme@mt*.ch*.se*

Navigate by Author: [Previous] [Next] [Author Search Index]
Navigate by Subject: [Previous] [Next] [Subject Search Index]

[Send Reply] [Send Message with New Topic]

[Search Selection] [Mailing List Home] [Home]