>Well for one reason, if you are filling Nitrox (by partial pressure >blending) at any of the dive shops in my area, they won't fill if you don't >have a Viton o-ring (and the magic sticker) as evidence of O2 clean tanks. By viton, what do they mean? Green, or brown? You'd think a reputable shop would know that there's more to O-rings - yoke seal Orings especially - than color. And anyhow, the proper hard yoke seal O-rings usually come in funny colors too, so how do they know they aren't viton? Of course, there's no law that says you have to have the same O-ring in the valve when you get it filled as when you dive. I hear they are not hard to change. BTW, Sherwood makes a O2 kit for their valves. Since they are a major valve OEM, one assumes they may have done their homework on the compound and duro. Don't know if they sell just the seal O-rings alone, and can't remember what color they were, but might be worth looking into. -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.