On Tue, 19 Sep 1995, Anthony D Montgomery wrote: > Points to consider: > 1. Failure points of a pressure gauge: > Gauge with hose: 3 o-rings, 1 hose, and the valve. > Gauge without hose: 1 o-ring, and the valve. The gauges-without-hose that are currently for sale have no valve, no hose, and only one o-ring, similar to the plugged high pressure port. > Plugged high pressure port: 1 o-ring. Nick Simicich - njs@sc*.em*.ne* - (last choice) njs@bc*.vn*.ib*.co* http://scifi.emi.net/njs.html -- Stop by and Light Up The World!