Christopher, Every panel meter has some degree of minor error. I think OMS uses a meter with a +/- 0.1% error and all others that I am aware of have a +/- 0.5% error. Do the math, not much difference. The most commonly used panel meter for home built O2 meters is the PM 128 (+/- 0.5% error). Another panel meter that is used for home building is the DVB3500B and I believe it has a +/- 0.1% error rate. Digi-Key also makes some really nice, compact digital panel meters ... they are about 1/3 the size of the typical meter. I think they run a +/- 0.2% error. The sensors also have error, the norm is within1% of full scale at constant temp and pressure for most sensors. Hope that helps. Regards, Patrick -- OxyCheq .... your source for oxygen sensors http://oxycheq.com Christopher Brown wrote: > What is the consensus on homemade 02 analyzers? Are > they accurate enough? > > What about flow-through vice "plug-in" quick > disconnect type 02 sensors? What is the accuracy of > the measurement in a flow through vice plug in 02 > sensor? > > __________________________________________________ > Do You Yahoo!? > Yahoo! Auctions - Buy the things you want at great prices. > http://auctions.yahoo.com/ > -- > Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. > Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'. -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.