Chris, I've made a couple and cross checked them against other homemade analyzers and factory made analyzers. All were about the same. My only complaint is the calibration adjustment is too sensitive. You can't beat the price of the homemade ones either. I have the LCD panel, rheostat, flow restrictor (set at 5lpm), battery, switch, and sensor mounted to a piece on aluminum insde an old Pelican case- all for under $100. It just took a rainy day to put it together. C ----- Original Message ----- From: Christopher Brown <hokiediver@ya*.co*> To: <techdiver@aquanaut.com> Cc: <vbtech@ci*.co*> Sent: Monday, March 12, 2001 10:49 PM Subject: Homemade 02 analyzers > What is the consensus on homemade 02 analyzers? Are > they accurate enough? > > What about flow-through vice "plug-in" quick > disconnect type 02 sensors? What is the accuracy of > the measurement in a flow through vice plug in 02 > sensor? > > > > __________________________________________________ > Do You Yahoo!? > Yahoo! Auctions - Buy the things you want at great prices. > http://auctions.yahoo.com/ > -- > Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. > Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'. -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.