Dave,

What is your normal dive profile?  When I did just one dive I was fine.  If
I do a deco dive of say 110-130 foot on air for 45 minutes (O2 deco) the
deco of the first dive would be a little longer than you would expect but if
you don't have a good set of tables you wouldn't know the difference.  My
biggest problem was on the repetitive dive.  When I would do back to back 45
minute profiles in the 110-130 range and deco on O2 with 2-hour surface
interval my second deco schedule would be really long (like hours) with
stops starting at 90 foot!

Just curious what kinds of dives you are doing.  Glad you had a better
experience.

Art.


	-----Original Message-----
	From:	O'Daniel, David [SMTP:David_O'Daniel@bs*.bl*.co*]
	Sent:	Tuesday, September 19, 2000 11:19 AM
	To:	'techdiver@aquanaut.com'
	Subject:	RE: Cochran Nemesis

	I own a Cochran Nemesis IIa Nitrox computer (hoseless) and have
logged
	somewhere in the neighborhood of 350 dives on it in the last 3
years,
	without a single failure or problem.  My dive partner used a Nemesis
IIa
	Nitrox for several years as well with a several hundred dives with
no
	failure as well.  In the last 5 or 6 months I have switched over to
a
	Commander Nitrox (non-air integrated) simply to do away with the air
	integration, I have logged another 80-100 dives on this computer
with no
	failure.  Neither computer has given me any problems, and I
recommend them,
	with one exception.  The data probe used for programming the mixes
into the
	Nemesis computers is just about the most annoying piece of sh!t
product I
	have ever used (another reason I switched over to the Commander
computer).
	Other than the frustration of having to clean the contacts time and
time
	again on the data probe for the Nemesis computers, I believe my
computers
	have worked quite well, perhaps I just got lucky.  Either way, I
felt the
	need to share my experiences with these products.  I do not have any
	experience with Cochran's customer service or representatives since
I have
	had no reason to contact them. 

	Dave
	www.technicaldiver.com 
	--
	Send mail for the `techdiver' mailing list to
`techdiver@aquanaut.com'.
	Send subscribe/unsubscribe requests to
`techdiver-request@aquanaut.com'.
--
Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'.
Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.

Navigate by Author: [Previous] [Next] [Author Search Index]
Navigate by Subject: [Previous] [Next] [Subject Search Index]

[Send Reply] [Send Message with New Topic]

[Search Selection] [Mailing List Home] [Home]