Subject: Re: aluminum cylinders for Decomixes
Date: Fri, 7 Jan 2000 19:56:08 -0500
From: Bill Wolk <BillWolk@ea*.ne*>
To: <MMikeodin@ao*.co*>, "Techdiver" <techdiver@aquanaut.com>
On1/7/00 9:36 AM, MMikeodin@ao*.co* wrote:

>I bought a couple of 80cft.alu to use them as stages as they affect the
>axial trim less than steels if you have them on the left.
>I've heared particulary from the ANDI corner that they may occur problems 
>with Aluminum cylinders and high O2 content.
>Any recommendations -beside of course O2-clean&compatible?

Mike -

Shows you the problem with ANDI. My suggestion is never, ever, ever again 
listen to the people who are feeding you the BS about AL tanks and high 
O2 gasses. (Rule #1)  AL tanks are fine -- zero problems -- with pure O2. 
The oxidation of aluminum cylinders -- unlike steels -- is self-limiting. 
 Luxfer tanks are O2 clean from the factory; most tank valves are 
likewise clean. Just put them together with a viton neck o-ring, an 
oxygen compatible thread lube and go diving.  As far as trim is 
concerned, use AL40s instead of 80s as sling bottles; they're more than 
enough for most ocean dives.



Best regards --

Bill

--