What is the expected (E(x)) rate of O2 convulsions when exposed to 100%
at 30 FSW? I have not found any expected rates for expsoures in the
range of 30-90 minutes as would occur with IWR. Realizing the high rate
of varability in human tolerance what is experienced in chamber operations?
This information is useful in evaluating the relative risk of IWR when
the optimal equipment configuration (is. FFW with gas switching
capabilities) is not available.
Curt
===========================================================================
Curt W. Smitka, Administrative Manager Phone: (313) 936-0702
Department of Environmental Fax: (313) 764-9424
and Industrial Health E-mail: CWSMITKA@UM*.ED*
School of Public Health
University of Michigan
===========================================================================
Navigate by Author:
[Previous]
[Next]
[Author Search Index]
Navigate by Subject:
[Previous]
[Next]
[Subject Search Index]
[Send Reply] [Send Message with New Topic]
[Search Selection] [Mailing List Home] [Home]