Mailing List Archive

Mailing List: techdiver

Banner Advert

Message Display

Subject: Re: SECOND STAGE FAILURE
Date: Sun, 27 Jun 1999 17:43:50 -0400
From: Bill Wolk <BillWolk@ea*.ne*>
To: "Christopher and Donna Cox" <hanalei@ma*.ul*.co*>,
     "Techdiver"
On6/28/99 1:53 PM, Christopher and Donna Cox wrote:

>He was diving a Sherwood Oasis approximatley 10 years old.
>While decompressing at 10 feet his second stage blew off at the the
>point where the hose meets the connection. Has anyone experienced this
>with any other type of gear?


Sounds like the second stage hose failed (where the swivel connector is 
crimped onto the hose), not the regulator. I've seen it happen before 
(fortunately at the surface) when bottles are turned on and that first 
blast of gas pressurizes the line.  What was left on the end of the hose? 
 

Glad to hear that you're both OK. Just another reminder to everyone out 
there to regularly inspect hoses and equipment before planning long deco 
dives.





Best regards --

Bill

--
Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'.
Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.

Navigate by Author: [Previous] [Next] [Author Search Index]
Navigate by Subject: [Previous] [Next] [Subject Search Index]