Callum Beveridge (cb@oa*.ic*.co*.uk*) writes:
2) Currently using the Buhlmann/Hahn tables (0-250m) but restricted to 63m
and
fairly limited bottom/stop time. Does anyone have more info on these
tables/
algorithms which would let me extend these limits? These tables suit our
style of diving in terms of stops and conservatism - any other 'similar'
tables
which would suit our needs?
Are you modifying the stops in these tables when you use O2 deco?
The only other readily available table which I think matches Buhlmann
in its conservatism is DCIEM. The advantage with the DCIEM tables
is that they include a schedule for O2 deco with reduced stops over
the air schedule. The O2 stop is at 6m.
I think Bill Mayne has covered most of the other points regarding
O2 service of regs/cylinders.
Greg Ryan gregr@cs*.su*.oz*.au*