On Thu, 25 Aug 1994, Harry Railing wrote: > Over here it is normal to fill with He first, then add O2 and then top off > with air. (He is added first because it is the most expensive). In this > scenario, pure O2 is passed through the pillar valve and therefore I suggest > that the tank and valve are in O2 service even though the end result might > be that there is less than FO2 40% once the He and O2 have mixed. Have to agree with ya here.. with experience dictating my reply.. in the begining there were a few of us that were passing o2 thru the valves in this manor without o2 servicing (not cleaned or no viton o rings), after we had the training we complied, but forgot about a couple of tanks in the madness... there were definite signs of degeneration on o rings upon later inspections *and* some minor leaks showed up in some valve knobs... aloha, dennis