From: "Thomas Kleemann (EED)" <Thomas.Kleemann@ee*.er*.se*>
To: techdiver@aquanaut.com
Subject: RE: 1st stage problem
Date: Wed, 22 May 2002 11:37:48 +0200
Hi Rich,

I guess you did a fast decent and tried to inflate during or 
immediately after that?

Than it's the known problem with the balance chamber bleeding system:
If the pressure in that chamber get lower than ambient 
(due to slow pressure buildup through the bleeding shingle) 
your relative IP will drop.

Poor design, but ignored by Sherwood. 

> Is this reg a bad choice for an argon reg? 

definitely :-(
intermittently use and denser gases may worsen the effect.

> What is the best reg to use for this purpose?

I use the Poseidon 1st stage with the OPV (but only because 
I got a spare one already ;-)
Apeks DS1 or DS4 would be the choice if you already took your 
other regs from the Apeks line (interchangeable spare parts).

HTH,
	Thomas. 

-----Original Message-----
From: Rich Gulley [mailto:richgulley@qw*.ne*]

I recently made a dive to 330' and just past 300' my argon inflation came very
slowly. Once back above 300' flow seemed to return to normal. I used a Sherwood
Brut and this was the deepest I've ever used that regulator. Tank pressure at
that point would have been well above 1000psi. The IP is set at 125psi. I'm not
exactly sure what went wrong or how to fix it. 
 
 
--
Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'.
Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.

Navigate by Author: [Previous] [Next] [Author Search Index]
Navigate by Subject: [Previous] [Next] [Subject Search Index]

[Send Reply] [Send Message with New Topic]

[Search Selection] [Mailing List Home] [Home]