At 07:48 8/01/2001 +0100, mat.voss@t-*.de* (Matthias Voss) wrote: >They said there was a chance of water entering via a too soft exhale >diaphragm, and latter should be replaced with a slightly stiffer one. >I had the problem, did the exchange, to no avail. I heard about that. They changed the mould so there's now a ridge of rubber across the diaphragm, at least I think that was the reason. >Real problem was, whenever swimming left side up, water seeped in by the >edge of the ventury adjustment knob. There was a sharp edge from the >pressuremoulding process left over. I smoothed it with a sharp knife and >honed it down, this worked, together with a new O-ring. >Btw, Apeks say you should do the replacement because of warranty. >There may have been another replacement of which I am currently not >aware. I hadn't heard about that one. Wonder if they've fixed the problem now? Simon Simon L Hartley RSM Website Coordinator\First Year Course Coordinator Associate Lecturer School of Resource Science and Management Southern Cross University P.O. Box 157 Lismore NSW, Australia 2480 Ph: (02) 66203251 or (61 66) 203 251 Fax:(02) 66212669 E-mail: shartley@sc*.ed*.au* http://wwwdev.scu.edu.au/staff_pages/shartley/ http://www.scu.edu.au/schools/rsm/ -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.