With Gue Decoplanner set at gf 20/90 90 meters, thirty minutes, trimix 12/50 deco: EAN32@39* meters, EAN50@21* and O2 at 6 meters gives me 58 minutes on O2, now what to do, do i break in cycles of 12 on and 6 off and count all the time as O2- deco, or should i do as one of my buddyes says, 20 minutes on O2, break 5 minutes and dont count the break? Einar ----- Original Message ----- From: Trey <trey@ne*.co*> To: Einar Hagen <einar.hagen@un*.co*> Cc: Techdiver <techdiver@aquanaut.com> Sent: Thursday, August 17, 2000 1:03 PM Subject: Re: O2-deco > 60 minutes O2 - that for me means an hour at 300 > feet. Show me the profile. > -----Original Message----- > From: Einar Hagen <einar.hagen@un*.co*> > To: trey@ne*.co* <trey@ne*.co*> > Cc: Techdiver <techdiver@aquanaut.com> > Date: Wednesday, August 16, 2000 6:26 PM > Subject: O2-deco > > > >I do dives that require me to do up to 60 minutes > >on O2. The way i have been doing this is 12 minutes > >on and 6 off, counting the breaks as O2 time. > > > >Today i was told that this was inapropriate for > >these kinds of profiles. What is the real deal? > > > > > >Einar > >--------------------------------------------------- > ----- > >I dont have a signature because they are > stupid...... > > > > > > -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.