Mailing List Archive

Mailing List: techdiver

Banner Advert

Message Display

From: <CaptnDale@ao*.co*>
Date: Sat, 27 May 2000 11:25:27 EDT
Subject: Re: [wkpp] Re: Rotated inflator?
To: trey@ne*.co*, wkpp@eg*.co*
CC: pst@in*.co*, techdiver@aquanaut.com
In a message dated 5/27/00 9:59:45 AM Central Daylight Time, trey@ne*.co* 
writes:

<< > When is doubt on anything as to the why's of DIR - my domain, ask me
and
 > cc the list. I would like to clear all of these items up since there are
 > so many "versions" of what I have tried to describe floating around out
 > there that are bullshit and unsupportable. >>

George,

In the last few weeks I have had three divers on my boat, each with the same 
problem.  They had leaking or extruded o-rings at the attachment point of the 
regulator hose to the first stage because they had assembled this connection 
only finger tight.  There was a discussion on this list a few weeks ago about 
leaving the second stage regulator connections only finger tight.  I think 
there have been some misunderstandings among those who do not think things 
through.  Please tell the list that you only leave the connection between the 
hose and the SECOND stage finger tight -- you must tighten the connection to 
the first stage.

Good diving,
Dale
--