They don't come tuned properly. Detune the 1st stage below 150psi and don't crank the 2nd stage past about 75% open. At 10:40 AM 4/28/2000 +0200, Matej Simonic / Testing LTD wrote: >Does anybody know what is the problem with Apex Tx40 (50) 1st stages >(membrane). Between our friends we have 5 Tx40 regs. They seem to have >some sort of problem with 1st stages. They leak slowly (we swapped the 2nd >stages and it did not help) so that you have continuous small stream of >bubbles coming out of the second stage. That happened in 2 cases. >We decided for Apex based on the list recommendations and we took membrane >dry 1st stages because we frequently dive in cold waters. Both leaking >regs are well maintained and almost new (in fact one came leaking new) and >the other has less than 20 dives. The rest of us are now very worried. >(because we thought we bought good regs...) >1) Is this common for TX40 (TX50 has the same 1st stage) and what shall I do. >2) What is the cause of this/how to solve it. > >Best Regards >Matej Simonic ---------------------------------- Kevin Connell <kevin@nw*.co*> NW Labor Systems, Inc http://www.nwls.com *I* moved your cheese. ---------------------------------- -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.