At 01:00 26.03.00 -0000, Paul Wright wrote:
>With the current UK/USA/Europe slight antagonism taking place it would be
>interesting to hear the views of the list members on the merits of DIN
>against A Clamp (US Fitting for pillar valve/regulator attachment.
One of the most important advantages of the DIN fitting is that the o-ring
is on the first stage, not the bottle. Blown o-rings should really not
happen this way.
All in all, the DIN way seems to me more secure. The A-clamp is probably
good enough for rec-diving, but I generally prefer the (subjective) feeling
of that little extra security the DIN connections provide.

Then again, I'm German and thus just used to it. Did use A-clamps on
holiday though and had no problems either.