Should you even use the 10' stop? Errols had told me in an e-mail a long time ago to not even use the 10'...since you aren't keeping the PO2 at 1.6 it wasn't worth it. I have cut them out since then, and set 20 as the last stop depth in ZPlan... Sean ----- Original Message ----- From: <kirvine@sa*.ne*> To: Gliviak, Jozef <Jozef.Gliviak@co*.co*> Cc: 'Shimell, David (shimell)' <shimell@se*.co*>; <techdiver@aquanaut.com> Sent: Thursday, December 16, 1999 3:46 PM Subject: Re: Bottom timer - any recomendations > I think David already said this, but the steps are not that precise. > Some of our guys use an Ironman watch countdown timer that they set for > each step, but we are talking very long steps. I carry one of them just > so I do not inadvertanly blow off a 100 minute chunk of deco. I do not > set the timer, I just note the time of day. > > BTW, Smithers Z Plan reruns the whole deco after separately figuring the > deep stops and the normal run. I run them separately. This is what is > giving you guys the bloated 10 foot stop. I think you can reverse the > ten and twenty foot times and treat the ten as an ascent to the surface > from 20 evenly in that amount of time. I can say that, but Will will > not. > > Gliviak, Jozef wrote: > > > > Try Z-plan with WKPP deco stops. They are in seconds. > > Or if you would like to know (control) your ascent rate in open water, It's > > helpfull to have seconds. > > > > The best I can imagine would have a second timer which you can easily reset. > > I never heard about such device. > > > > Regards > > > > Jozef Gliviak > > Slovakia > > > > -----Original Message----- > > From: Shimell, David (shimell) [mailto:shimell@se*.co*] > > Sent: Thursday, December 16, 1999 4:54 PM > > To: Gliviak, Jozef > > Subject: RE: Bottom timer - any recomendations > > > > Jozef > > > > Why are you concerned about reading to the second? > > > > David Shimell > > Email: shimell@se*.co* <mailto:shimell@se*.co*> > > Project Manager, IBM NUMA-Q, Sequent Computer Systems Limited, > > Weybridge Business Park, Addlestone Road, Weybridge, Surrey, KT15 2UF, UK > > registered in England and Wales under company number: 1999363, registered > > office as above > > > > -- > > Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. > > Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'. > > -- > Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. > Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'. -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.
Navigate by Author:
[Previous]
[Next]
[Author Search Index]
Navigate by Subject:
[Previous]
[Next]
[Subject Search Index]
[Send Reply] [Send Message with New Topic]
[Search Selection] [Mailing List Home] [Home]