Marty, thanks for the references - I will pass them on for the know it
alls to argue about .

Karen, read the references below Marty's message and get back to us in
about ten years when you know what you are talking about , if then.

marty hopkins wrote:
> 
> These people are starting to piss me off ...
> 
> I agree 100% on the use of the reg for resuscitation ...
> Anybody who can't see the advantages ...
> especially if you have a high 02 mix ????????
> 
> What is this nonsense they are spouting about compleatly sealing the reg
> exhaust?
> With the nose sealed and a good mouth seal ...
> An unconscious lung will inflate if the airway is open ...
> Sealing the exhaust ports would be dangerous.
> I know you can inhibit flow out the exhaust with your fingers for obvious
> reasons ...
> But compleatly sealing it would be dangerous because of the positive
> pressures you could generate.
> My LSP surface rescitator unit (pos Pressure)has an exhaust system in the
> resuscitator head that works just like a reg exhaust ...
> What's the difference?
> 
> Thought I'd  pass these references along ...
> I'm sure your alredy aware of a lot of it ...
> I haven't had a chance to look at any of them yet myself ...
> 
> This one caught my eye ...
> Corley M, Ledwidge MK, Glass C, Grap MJ.
> The myth of 100% oxygen delivery through manual resuscitation bags.
> J Emerg Nurs. 1993;19:45-9.
> 
> All the Best ...
> 
> Marty H    Canada
> 
> P.S. Beginning to understand why you call these people strokes
>      Feel free to distribute this message if I'm not out to lunch on this
> ...
> 
> Complete Bibliography at: http://www.umdnj.edu/rspthweb/bibs/bvm.htm
> 
> End This Message
> 
> Text Bibliography Follows ---------------------
> 
> Bag-Valve-Mask Ventilation (Manual Ventilation)
> Gazmuri RJ. Airway management during cardiopulmonary resuscitation: a
> shifting paradigm [editorial; comment]. Crit Care Med. 1999;27:27-8.
> 
> Marshak AB, Scanlan CL; Emergency life support. In: Scanlan CL, Wilkins RL,
> Stoller JK, Eds. Egan's Fundamentals of Respiratory Care. 7 ed. St. Louis:
> Mosby; 1999.
> 
> Auble TE, Menegazzi JJ, Nicklas KA. Comparison of automated and manual
> ventilation in a prehospital pediatric model. Prehosp Emerg Care.
> 1998;2:108-11.
> 
> Cantello E, Davy TE, Koenig KL. The question of removing a ventilation bag
> before defibrillation [letter]. J Accid Emerg Med. 1998;15:286.
> 
> Dunkley CJ, Thomas AN, Taylor RJ, Perkins RJ. A comparison of standard and a
> modified method of two resuscitator adult cardiopulmonary resuscitation:
> description of a new system for research into advanced life support skills.
> Resuscitation. 1998;38:7-12.
> 
> Kornegay HB Jr, Carroll RG, Brown LH, Whitehurst ME. A comparison of
> demand-valve and bag-valve ventilations in a swine pneumothorax model. Acad
> Emerg Med. 1998;5:977-81.
> 
> Osterwalder JJ, Schuhwerk W. Effectiveness of mask ventilation in a training
> mannikin. A comparison between the Oxylator EM100 and the bag-valve device.
> Resuscitation. 1998;36:23-7.
> 
> Platt TE, Menegazzi JJ, Check BD. A randomized, crossover comparison of
> various ventilation devices in a swine pneumothorax model. Prehosp Emerg
> Care. 1998;2:167-9.
> 
> Stone BJ, Chantler PJ, Baskett PJ. The incidence of regurgitation during
> cardiopulmonary resuscitation: a comparison between the bag valve mask and
> laryngeal mask airway. Resuscitation. 1998;38:3-6.
> 
> Updike G, Mosesso VN Jr, Auble TE, Delgado E. Comparison of bag-valve-mask,
> manually triggered ventilator, and automated ventilator devices used while
> ventilating a nonintubated mannikin model. Prehosp Emerg Care. 1998;2:52-5.
> 
> Wenzel V, Idris AH, Banner MJ, et al. Influence of tidal volume on the
> distribution of gas between the lungs and stomach in the nonintubated
> patient receiving positive-pressure ventilation. Crit Care Med.
> 1998;26:364-8.
> 
> American Society for Testing and Materials; Standard Specification for
> Minimum Performance and Safety Requirements for Resuscitators Intended for
> Use With Humans. F920-93. West Conshohocken, PA: ASTM; 1997.
> 
> Martell RJ, Soder CM. Laerdal infant resuscitators are unreliable as
> free-flow oxygen delivery devices. Am J Perinatol. 1997;14:347-51.
> 
> Mondolfi AA, Grenier BM, Thompson JE, Bachur RG. Comparison of
> self-inflating bags with anesthesia bags for bag-mask ventilation in the
> pediatric emergency department. Pediatr Emerg Care. 1997;13:312-6.
> 
> Wheatley S, Thomas AN, Taylor RJ, Brown T. A comparison of three methods of
> bag valve mask ventilation. Resuscitation. 1997;33:207-10.
> 
> Baskett P, Nolan J, Parr M. Tidal volumes which are perceived to be adequate
> for resuscitation. Resuscitation. 1996;31:231-4.
> 
> Brenner BE, Kauffmann J. Response to cardiac arrests in a hospital setting:
> delays in ventilation. Resuscitation. 1996;31:17-23.
> 
> Emergency Care Research Institute. Infection Control and Pulmonary
> Resuscitators. Plymouth Meeting, PA: Emergency Care Research Institute;
> 1996; Healthcare Risk Control; 4.
> 
> Emergency Care Research Institute. Mislocated pop-off valve can produce
> airway overpressure in manual resuscitator breathing circuits. Health
> Devices. 1996;25:212-4.
> 
> European Resuscitation Council. Airway and Ventilation Management of the
> Working Group . Guidelines for the advanced management of the airway and
> ventilation during resuscitation. Resuscitation. 1996;31:201-30.
> 
> Ho AM, Shragge BW, Tittley JG, et al. Exhalation obstruction due to Laerdal
> valve misassembly. Crit Care Med. 1996;24:362-4.
> 
> Johannigman JA, Branson RD. Ventilatory support in the field. Respir Care
> Clin North Am. 1996;2:353-389.
> 
> Monem GF, Kissoon N, Murphy S, et al. Manual volume-controlled ventilation
> in preterm neonates compared to ventilation via self-inflating resuscitator.
> Respir Care. 1996;41:1083-1089.
> 
> Reickjr CW. Auto-PEEP associated with excessive oxygen flow through five
> manual resuscitators. Respir Care. 1996;41:1009-1012.
> 
> Silbergleit R, Lee DC, Blank-Reid C, McNamara RM. Sudden severe barotrauma
> from self-inflating bag-valve devices. J Trauma. 1996;40:320-2.
> 
> Bircher NG; Cardiopulmonary resuscitation. In: Dantzker DR, MacIntyre NR,
> Bakow ED, Eds. Comprehensive Respiratory Care. Philadelphia: WB Saunders;
> 1995.
> 
> Branson RD, Johannigman JA. Ventilatory support during cardiopulmonary
> resuscitation. Respir Care. 1995;40:479-97.
> 
> Johannigman JA; Prehospital respiratory care. In: Dantzker DR, MacIntyre NR,
> Bakow ED, Eds. Comprehensive Respiratory Care. Philadelphia: WB Saunders;
> 1995.
> 
> Barnes TA, Watson ME; Cardiopulmonary resuscitation and emergency cardiac
> care. In: Barnes TA, Ed. Core Textbook of Respiratory Care Practice. 2 ed.
> St. Louis: Mosby-Year Book; 1994.
> 
> Eubanks DH, Bone RC. Principles and Applications of Cardiorespiratory
> Equipment. 3 ed. St. Louis: Mosby-Year Book; 1994.
> 
> Nobel JJ. Pulmonary exhaled-air resuscitators: manual, reusable; manual,
> disposable. Pediatr Emerg Care. 1994;10:44-7.
> 
> Pepe PE; Delivery of mechanical ventilation during resuscitation. In: Tobin
> MJ, Ed. Principles and Practice of Mechanical Ventilation. New York:
> McGraw-Hill; 1994.
> 
> Alexander R, Hodgson P, Lomax D, Bullen C. A comparison of the laryngeal
> mask airway and Guedel airway, bag and facemask for manual ventilation
> following formal training. Anaesthesia. 1993;48:231-4.
> 
> American Association for Respiratory Care. Clinical practice guideline.
> Resuscitation in acute care hospitals. Respir Care. 1993;38:1179-1188.
> 
> Connors R, Kissoon N, Tiffin N, Frewen TC. An evaluation of the physical and
> functional characteristics of infant resuscitators. Pediatr Emerg Care.
> 1993;9:104-7.
> 
> Corley M, Ledwidge MK, Glass C, Grap MJ. The myth of 100% oxygen delivery
> through manual resuscitation bags. J Emerg Nurs. 1993;19:45-9.
> 
> Glass C, Grap MJ, Corley MC, Wallace D. Nurses' ability to achieve
> hyperinflation and hyperoxygenation with a manual resuscitation bag during
> endotracheal suctioning. Heart Lung. 1993;22:158-65.
> 
> Hess D, Simmons M, Blaukovitch S, et al. An evaluation of the effects of
> fatigue, impedance, and use of two hands on volumes delivered during
> bag-valve ventilation. Respir Care. 1993;38:271-5.
> 
> Hess D, Simmons M, Slikkers F, Dickerson R. Resistance to flow through the
> valves of mouth-to-mask ventilation devices. Respir Care. 1993;38:183-8.
> 
> Kissoon N, Monem G, Murphy S, et al. Measuring total pulmonary compliance
> with a volume-controlled infant resuscitator: a bench study. Respir Care.
> 1993;38:985-92.
> 
> Kissoon N, Tiffin N. Additional data on emergency ventilation equipment.
> Respir Care. 1993;38:207.
> 
> Martin PD, Cyna AM, Hunter WA, et al. Training nursing staff in airway
> management for resuscitation. A clinical comparison of the facemask and
> laryngeal mask. Anaesthesia. 1993;48:33-7.
> 
> McCabe SM, Smeltzer SC. Comparison of tidal volumes obtained by one-handed
> and two-handed ventilation techniques. Am J Crit Care. 1993;2:467-73.
> 
> Reiterer F, Sivieri E, Abbasi S, Bhutani VK. Evaluation of pulmonary
> functions during pressure-limited manual ventilation in preterm neonates.
> Pediatr Pulmonol. 1993;15:117-21.
> 
> Thomas AN, O'Sullivan K, Hyatt J, Barker SJ. A comparison of bag mask and
> mouth mask ventilation in anaesthetised patients. Resuscitation.
> 1993;26:13-21.
> 
> Barnes TA. Emergency ventilation techniques and related equipment. Respir
> Care. 1992;37:673-90.
> 
> Hess D, Simmons M. An evaluation of the resistance to flow through the
> patient valves of twelve adult manual resuscitators. Respir Care.
> 1992;37:432-8.
> 
> Kissoon N, Connors R, Tiffin N, Frewen TC. An evaluation of the physical and
> functional characteristics of resuscitators for use in pediatrics. Crit Care
> Med. 1992;20:292-6.
> 
> Krapf R, Loiacono J, Pesola GR, Carlon GC. Ventilatory support during
> magnetic resonance imaging. Chest. 1992;102:632-3.
> 
> Milner AD, Stokes GM, Tunell R, et al. Laboratory assessment of Laerdal
> mouth tube mask prototype resuscitation device. Med Biol Eng Comput.
> 1992;30:117-9.
> 
> Stemp LI. Manual resuscitators and spontaneous ventilation--an evaluation
> [letter; comment]. Crit Care Med. 1992;20:1496.
> 
> Barnes TA, Stockwell DL. Evaluation of ten manual resuscitators across an
> operational temperature range of -18 degrees C to 50 degrees C. Respir Care.
> 1991;36:161-72.
> 
> Fluck RR Jr, Sorbello JG. Comparison of tidal volumes, minute ventilation,
> and respiratory frequencies delivered by paramedic and respiratory care
> students with pocket mask versus demand valve. Respir Care. 1991;36:1105-12.
> 
> Hird MF, Greenough A, Gamsu HR. Inflating pressures for effective
> resuscitation of preterm infants. Early Hum Dev. 1991;26:69-72.
> 
> Johannigman JA, Branson RD, Davis K Jr, Hurst JM. Techniques of emergency
> ventilation: a model to evaluate tidal volume, airway pressure, and gastric
> insufflation. J Trauma. 1991;31:93-8.
> 
> Johannigman JA, Branson RD. Oxygen enrichment of expired gas for
> mouth-to-mask ventilation. Respir Care. 1991;36:99-103.
> 
> Kissoon N, Nykanen D, Tiffin N, et al. Evaluation of performance
> characteristics of disposable bag-valve resuscitators. Crit Care Med.
> 1991;19:102-7.
> 
> Mills PJ, Baptiste J, Preston J, Barnas GM. Manual resuscitators and
> spontaneous ventilation--an evaluation. Crit Care Med. 1991;19:1425-31.
> 
> Upton CJ, Milner AD. Endotracheal resuscitation of neonates using a
> rebreathing bag. Arch Dis Child. 1991;66:39-42.
> 
> Barnes TA, McGarry WP 3d. Evaluation of ten disposable manual resuscitators.
> Respir Care. 1990;35:960-8.
> 
> Emergency Care Research Institute. Pulmonary resuscitators: preventing cross
> contamination. Tech Respir Ther. 1990;10:1-6.
> 
> Hess D, Spahr C. An evaluation of volumes delivered by selected adult
> disposable resuscitators: the effects of hand size, number of hands used,
> and use of disposable medical gloves. Respir Care. 1990;35:800-5.
> 
> Kissoon N, Frewen T, Tiffin N. Prototype volume-controlled resuscitator for
> neonates and infants. Crit Care Med. 1990;18:1430-4.
> 
> Munford BJ, Wishaw KJ. Critical incidents with nonrebreathing valves.
> Anaesth Intensive Care. 1990;18:560-3.
> 
> Stone KS. Ventilator versus manual resuscitation bag as the method for
> delivering hyperoxygenation before endotracheal suctioning. AACN Clin Issues
> Crit Care Nurs. 1990;1:289-99.
> 
> An evaluation of eight disposable and two non-disposable adult
> resuscitators. RRT. 1989;25:13-9.
> 
> Ventilation bags can be heavily colonized if not cleaned daily. Hosp Infect
> Control. 1989;16:23-4.
> 
> Barnes TA, Potash R. Evaluation of five adult disposable operator-powered
> resuscitators. Respir Care. 1989;34:254-61.
> 
> Baum M, Benzer H, Putensen C, et al. Biphasic positive airway pressure
> (BIPAP)--a new form of augmented ventilation. Anaesthesist. 1989;38:452-8.
> 
> Emergency Care Research Institute. Pulmonary resuscitators. Health Devices.
> 1989;18:333-52.
> 
> Goldstein B, Catlin EA, Vetere JM, Arguin LJ. The role of in-line manometers
> in minimizing peak and mean airway pressure during the hand-regulated
> ventilation of newborn infants. Respir Care. 1989;34:23-7.
> 
> Hedley-Whyte J. US and international standards for resuscitators [letter].
> JAMA. 1989;261:1880.
> 
> Hess D, Goff G, Johnson K. The effect of hand size, resuscitator brand, and
> use of two hands on volumes delivered during adult bag-valve ventilation.
> Respir Care. 1989;34:805-10.
> 
> Hess D, Ness C, Oppel A, Rhoads K. Evaluation of mouth-to-mask ventilation
> devices. Respir Care. 1989;34:191-5.
> 
> Hurst JM, Davis K Jr, Branson RD, Johannigman JA. Comparison of blood gases
> during transport using two methods of ventilatory support. J Trauma.
> 1989;29:1637-40.
> 
> Laxton AG. Occasional paediatric resuscitation: misuse of equipment
> [letter]. Anaesthesia. 1989;44:84.
> 
> Terndrup TE, Kanter RK, Cherry RA. A comparison of infant ventilation
> methods performed by prehospital personnel. Ann Emerg Med. 1989;18:607-11.
> 
> Campbell TP, Stewart RD, Kaplan RM, et al. Oxygen enrichment of
> bag-valve-mask units during positive-pressure ventilation: a comparison of
> various techniques. Ann Emerg Med. 1988;17:232-5.
> 
> Emergency Care Research Institute. Mismating of Laerdal exhalation diverters
> and Intertech masks [hazard]. Tech Respir Ther. 1988;8:1-2.
> 
> Emergency Care Research Institute. Interchanging Laerdal and Solco
> resuscitators and components [hazard]. Tech Respir Ther. 1988;8:3-4.
> 
> Hartstein AI, Rashad AL, Liebler JM, et al. Multiple intensive care unit
> outbreak of Acinetobacter calcoaceticus subspecies anitratus respiratory
> infection and colonization associated with contaminated, reusable ventilator
> circuits and resuscitation bags. Am J Med. 1988;85:624-31.
> 
> Arellano R, Ross D, Lee K. Inappropriate attachment of PEEP valve causing
> total obstruction of ventilation bag [letter]. Anesth Analg. 1987;66:1050-1.
> 
> Emergency Care Research Institute. Inspiron disposable adult manual
> pulmonary resuscitators [hazard]. Tech Respir Ther. 1987;8:1-2.
> 
> Emergency Care Research Institute. Reprocessing and inspection of manual
> pulmonary resuscitators [hazard]. Tech Respir Ther. 1987;8:2-3.
> 
> Hess D, Goff G. The effects of two-hand versus one-hand ventilation on
> volumes delivered during bag-valve ventilation at various resistances and
> compliances. Respir Care. 1987;32:1025-8.
> 
> Cramond T, O'Callaghan JP. The Combibag: an evaluation of a new
> self-inflating resuscitator. Anaesth Intensive Care. 1986;14:66-9.
> 
> Cramond T, Mead P. Non-rebreathing valve assembly [letter]. Anaesth
> Intensive Care. 1986;14:465.
> 
> Cramond T, O'Callaghan J. Re: A new non-rebreathing valve for mouth-mask
> ventilation [letter]. Anaesth Intensive Care. 1986;14:93.
> 
> Field D, Milner AD, Hopkin IE. Efficiency of manual resuscitators at birth.
> Arch Dis Child. 1986;61:300-2.
> 
> Hess D, Baran C. Ventilatory volumes using mouth-to-mouth, mouth-to-mask,
> and bag- valve techniques... a resuscitation manikin. Respir Care.
> 1986;31:774-9.
> 
> MacNeil A. Oxygen reservoir for mouth-valve-mask resuscitation [letter].
> Anaesth Intensive Care. 1986;14:468.
> 
> Phillips GD, Skowronski GA. Manual resuscitators and portable ventilators.
> Anaesth Intensive Care. 1986;14:306-13.
> 
> Emergency Care Research Institute. New ASTM standard for resuscitators. Tech
> Respir Ther. 1985;6:2-3.
> 
> Stewart RD, Kaplan R, Pennock B, Thompson F. Influence of mask design on
> bag-mask ventilation. Ann Emerg Med. 1985;14:403-6.
> 
> Bumstead D. A modification of the Laerdal infant resuscitator for the simple
> and safe delivery of CPAP and PEEP. Respir Care. 1984;29:270-2.
> 
> Eross B, Tobias J, Hrehocik AJ, Kern CF. Instant oxygen delivery system for
> manual resuscitators. Respir Care. 1984;29:919-21.
> 
> Olver JJ, Pope R. Potential hazard with silicone resuscitators [letter].
> Anaesthesia. 1984;39:933-4.
> 
> Barnes TA, Watson ME. Oxygen delivery performance of old and new designs of
> the Laerdal, Vitalograph and Ambu adult manual resuscitators. Respir Care.
> 1983;28:1121-28.
> 
> Hill SL, Eaton JM. Rebreathing during use of the Air-Viva resuscitation bag:
> a hazard. Br Med J (Clin Res Ed). 1983;287:583-4.
> 
> Barnes TA, Watson ME. Oxygen delivery performance of four adult
> resuscitation bags. Respir Care. 1982;27:139-46.
> 
> A simple PEEP system for the Laerdal resuscitation bag. Respir Ther.
> 1981;11:120.
> 
> LeBouef LL. 1980 assessment of eight adult manual resuscitators. Respir
> Care. 1980;25:1136-42.
> 
> Klick JM, Bushnell LS, Bancroft ML. Barotrauma, a potential hazard of manual
> resuscitators. Anesthesiology. 1978;49:363-5.
> 
> Fierer J, Taylor PM, Gezon HM. Contaminated resuscitators: fatal threat to
> newborns. Hosp Top. 1968;46:77-9.
> 
> Fierer J, Taylor PM, Gezon HM. Pseudomonas aeruginosa epidemic traced to
> delivery-room resuscitators. N Engl J Med. 1967;276:991-6.
> 
> ----------------------------------------------------------------------------
> ----
> 
> Compiled 7/30/99. Based on MedLine Update through June, 1999. A Scanlan
> Bibliography


--
Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'.
Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.

Navigate by Author: [Previous] [Next] [Author Search Index]
Navigate by Subject: [Previous] [Next] [Subject Search Index]

[Send Reply] [Send Message with New Topic]

[Search Selection] [Mailing List Home] [Home]