Mailing List Archive

Mailing List: techdiver

Banner Advert

Message Display

Date: Mon, 23 Nov 1998 20:27:12 -0500
From: "Case E. Harris" <diveman@cy*.co*>
To: Phi Le <PLe@Se*.co*>
CC: techdiver@aquanaut.com
Subject: Re: CORRECT BOTTLE ID'S
Phi-

Hmm...interesting point. In my experience, very few regs are SO
DIS-SIMILAR that they wouldn't function (at least on a minimal level)
when stages are swapped around. I use a Scubapro Mk20 for my O2 reg, and
a Sherwood Maximus for my 36% (or intermediate mix). Both of these regs
function fairly well with each other's second stages (Not up to factory
spec, but certainly enough to keep you alive and comfortable!) And yeah,
the second stages are attached finger tight so I can swap them if I had
to. I can honestly say that my choice of regs was based on what was
around in the shop at the time, not going out of my way to have the best
of the best all around. (I do think shop employees have an obligation to
dive what the shop sells....of course I wouldn't work in a shop that
didn't sell something good and safe to use!)

Both of my stage regs are DIN, and I (I may have misunderstood your
point about din/yoke) don't understand why you couldn't swap out a whole
DIN reg U/W in an emergency....sure, a bit more twisting and screwing,
but not harder than a yoke...(yes, I've tried it!)

I think that when the fit hits the shan, most combinations of regs will
work with each other's second stages. Again, perhaps not to factory
spec, but certainly enough to keep you alive!  Now, if you're using a
G-250 and  a Poseidon, you're screwed....but who would do that anyway?
No one _I_ would dive with!

Safe diving!
-Case
diveman@cy*.co*

Phi Le wrote:
> 
> Case,
> 
> I understand the advantage with 'touch distinguished regulators' as
> outlined below. How do you feel concerning 2nd stage malfunctioning
> on 1 of the deco regulators ?
> 
> If both regulators are identical, you could simply switch 2nd stages.
> Otherwise, you might not be able to do so (fitting, IP, etc.). Of course,
> if you are using yoke then you could switch the whole regulator.
> I assume everybody uses DIN connection on deco/stage bottles,
> except for Jess Armantrout for reasons he stated earlier this year :)
> 
> Phi
<<<my old post deleted>>>
-- 

                 \  \      
^_              \  \                 Case E. Harris
  \ \             {   \         US Deep Wreck Diving Team
  {  \           /     `~~~--__   diveman@cy*.co*
  {   \___----~~'              `~~-_   
   \                         /// `  `~.           ___  Oo
   / /~~~~-, ,__.    ,      ///  __,,,,)         (___)o_o
   \/      \/    `~~~;   ,---~~-_`~=        //====--//(_)
                    /   /                           \\ ^ 
                   '._.'   Deep...Professional...The Standard!
--
Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'.
Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.

Navigate by Author: [Previous] [Next] [Author Search Index]
Navigate by Subject: [Previous] [Next] [Subject Search Index]

[Send Reply] [Send Message with New Topic]