Mailing List Archive

Mailing List: techdiver

Banner Advert

Message Display

From: "Richard Hayward" <hddiver@ic*.ne*>
To: "techdiver" <techdiver@aquanaut.com>
Subject: Re: Cold water performance of Scuba Pro Regs
Date: Thu, 19 Feb 1998 12:42:45 -0800
This is a multi-part message in MIME format.

------=_NextPart_000_002E_01BD3D33.E049C7C0
Content-Type: text/plain;
	charset="iso-8859-1"
Content-Transfer-Encoding: 7bit

Hi Hans,

Well Personally I do not think, it was an HP leaks in the first stage, even
if that was the case I would have expected the second stage to begin free
flowing. The reg was dry when put on the tank, as soon as the system was
pressurized it started to leak, I thought that the o-ring on one of the
hoses must have went and when I was looking for the leak, I determined it
was coming from the body of the first stage from under the swivel, I have
not had the chance to repair it yet, I am considering sending it back (only
10 dives on it) needless to say, my dive partner doesn't really want it
anymore.

The Apek version without the swivel really interests me where can I get
information on it?

Is there a true Apek dealer in North America or would I have to order a reg
from Europe.

Take care

Richard Hayward
-----Original Message-----
From: Hans Petter Roverud <proverud@on*.no*>
To: Richard Hayward <hddiver@ic*.ne*>
Date: February 19, 1998 9:12 AM
Subject: Re: Cold water performance of Scuba Pro Regs


>At 09:33 19.02.98 -0800, you wrote:
>>As a matter of fact the other day I was out again in the St Marys River
>>between Lake Superior and Huron(32 degrees and 4 knot current), and my
>>friends Zeagle Tek 50 severe blew an o-ring on the on the swivel (the part
>>where the lp hoses attach and allow the attached lp hoses to move around
>>freely on the body) on the first stage, this reg had only 10 dives on it
at
>>most. I had to shake my head, because luckily this happened on the surface
>>on the predive and not in the water, it leaked air as if there was on open
>>port on the first stage.
>>
>>I have never liked those lp hose swivel (like on the Dacor, Scuba Pro,
>>Zeagle etc) and consider them a point for failure, it is just one extra
>>o-ring to worry about.
>
>I've got the same reg without the swivel. They come with the option of
>several first stage configs. However, do you think this happened due to a
>first stage failure (leaking HP to the LP side) or was it simply a matter
of
>a brittle O-ring? If it was a true freeze-up I would have expected the
>second stage to start letting off the excess (it's downstream) before
>anything else would snap.
>
>regards,
>
>Hans, Norway
>
>PS These regs are actually manufactured by Apeks in Britain. We know it as
>"Apeks TX50". Zeagle is the US importer and wholesaler. The Apeks regs look
>very much like a basic Scubapro design, yet our experience is that they
>don't freeze up as easily. I don't really know what is different about the
>second stage, but the first stage has a patented dry seal. Instead of water
>on the outside spring there's an air filled space sealed with a membrane
>that transfers the ambient pressure.
>

------=_NextPart_000_002E_01BD3D33.E049C7C0
Content-Type: text/x-vcard;
	name="Richard JW Hayward.vcf"
Content-Transfer-Encoding: quoted-printable
Content-Disposition: attachment;
	filename="Richard JW Hayward.vcf"

BEGIN:VCARD
N:Hayward;Richard;JW
FN:Richard JW Hayward
ORG:HD Diving Services;Contracting
TITLE:Owner/Operator
TEL;WORK;VOICE:(705) 949-3431
TEL;HOME;VOICE:(705) 949-3431
TEL;CELL;VOICE:(705) 946-9380
TEL;WORK;FAX:(705) 949-1580
TEL;HOME;FAX:(705) 949-1580
ADR;WORK:;Services;23 Montgomery Avenue B;Sault Ste. Marie;Ontario;P6B =
1M4;Canada
LABEL;WORK;ENCODING=3DQUOTED-PRINTABLE:Services=3D0D=3D0A23 Montgomery =
Avenue B=3D0D=3D0ASault Ste. Marie, Ontario P6B 1M4=3D
=3D0D=3D0ACanada
ADR;HOME:;;23 Montgomery Avenue;Sault Ste. Marie;Ontario;P6B 1M4;Canada
LABEL;HOME;ENCODING=3DQUOTED-PRINTABLE:23 Montgomery =
Avenue=3D0D=3D0ASault Ste. Marie, Ontario P6B 1M4=3D0D=3D0ACanada
EMAIL;PREF;INTERNET:hddiver@ic*.ne*
EMAIL;INTERNET:hdnitrox@ho*.co*
END:VCARD

------=_NextPart_000_002E_01BD3D33.E049C7C0--

--
Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'.
Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.

Navigate by Author: [Previous] [Next] [Author Search Index]
Navigate by Subject: [Previous] [Next] [Subject Search Index]

[Send Reply] [Send Message with New Topic]

[Search Selection] [Mailing List Home] [Home]