Date: Mon, 08 Dec 1997 06:25:37 -0800
To: "Atle Aamodt" <aaamodt@on*.no*>
From: Kevin Connell <kevin@nw*.co*>
Subject: Re: Speaking of Idiots
Cc: techdiver@aquanaut.com
There are three obvious things wrong with this stupidity

1) You are diving independent twins: See the discussion in the archives on
independent twins.

2) You are unnecessarily convoluting your setup: Either dive with a single
tank, or leave the damn valve open. 

3) What's the point of shutting it anyway?  It doesn't save any gas.  


At 10:57 AM 12/8/97 +0100, you wrote:
>
>> I did a trimix course with Kevin Gurr earlier on this year. Diving with
>the
>> isolator shut to "save gas" certainly was not part of the course.
>However,
>> on the way back from a dive he did mention that on a short dive, diving
>> with, say, twin 15L cylinders he would have the isolator shut. He would
>then
>> only have to dump and refill 15L instead of 30L. Is this really so bad?
>If
>> he had a problem It takes a second to reach behind and open the isolator.
>> 
>
>What kind of problem could occur ?
>
>1.	Emty bottle ? So what. Switch to the secondary regulator. And/Or open
>the isolator.
>2.	Second stage failure ? So what. Switch to the secondary regulator, close
>the valve to the bad 	regulator and open the isolator.
>3.	First stage failure ? So what. Switch to the secodary regulator, close
>the valve to the bad stage 	and open the isolator
>4.	Broken HP gauge or hose ? So what. Switch to the secodary regulator,
>close the valve with the 	bad hose and the isolator prevent loosing gas.
>5.	Broken LP inflator or hose. So what. Switch to the secodanry regulator,
>close the valve with bad 	hose/inflator and the isolator prevent loosing
>gas.
>
>Maybe I'm way out on this one. Flame me if you like, but what can possibly
>be wrong with this.
>
>Atle Aamodt
>
>
>
--------------------------------------------------------------------------
Kevin Connell <kevin@nw*.co*>

Northwest Labor Systems
http://www.nwls.com
Bellingham, WA
---------------------------------------------------------------------------
--
Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'.