On Mon, 1 Dec 1997, Phi Le wrote:

> With all the bashing on the Cochran Nemesis IIa, if anyone really had
> first hand experience, please elaborate. 

Phi Le,

I own two Nemesis Nitrox IIa's.  I bought both of them used, and very
cheap.  ($250 each).  At that price, you kinda have to expect them to
flakey.  And they were.  After about ten dives, one started reading 50-80
bar lower than the actual pressure.  The annoying part was all the out of
air alarms.  After about 15 dives, the other one's pressure reading would
slowely creep up to about 500 bar by the end of the dive.  Only the air
data was bad.  The ongassing calculations were still accurate.  I sent
both of them in for repairs, and Cochran replaced both tank units for
free.  I was very impressed with that since I was not the origional owner.
Since then, both have been problem free, only about 100 more dives on
them.

All, in all, I am pleased with my IIa's.

Andrew Drapp

 

--