Subject: Re: O2 clean VLPost-Roger
Roger Lacasse wrote:

> heard/read about. It allways seems to happen when a valve is openned too
> quickly.


Yeah, that's why ball valves are not recommended in O2 service...they're
quarter-turn valves and it's relatively easy for the clueless or
forgetfull to just crank open the handle in a second. 

I suppose a ball valve would actually be a good valve for O2 - very
little pressure drop due to "flow-through" design, and not much of the
valve is exposed to direct flow - if it were equipped with a gear-driven
actuator to slow down the opening/closing.

But there'd be a cost a cost penalty.