Here is a chart of regulator performance from tests conducted by US Antarctic Program from '89 thru '95. The data was accumulated by Jeff Bazanic and Jim Mastro. All dives were conducted in McMurdo Sound, Antarctica. Water temp range -1.9C to -1.2C. All failures were due to free flow. FFM dives were done in Dry Valley lakes. Water temp 0C. Based on these tests, USAP now issues Maximus regulators. As mentioned earlier, we have had NO failures for past two seasons having made approximately 2000 dives on the regs during that time. Hope the information is of value. Rob Robbins Scientific Diving Coordinator US Antarctic Program Regulator Type # Dives # Failures % Failure Sherwood Maximus 1341 23 1.7% Sherwood Blizzard 2 2 100.0% Poseidon Cyklon 300 710 40 5.6% Poseidon Odin 270 15 5.6% US Divers RAM 259 45 17.4% US Divers Arctic Supreme 7 4 57.1% US Divers Pro Diver 3 2 66.7% US Divers Conshelf Supreme 7 4 57.1% Scubapro Mk10/G200 27 13 48.1% Scubapro Mk10/D350 17 3 17.6% Scubapro Mk200/G200 8 8 100.0% Scubapro Mk10/D400 7 1 14.3% Scubapro Mk10/Polar 6 2 33.3% Scubapro Mk10/G250 1 1 100.0% Dacor Extreme Ice 25 4 16.0% Mares MR-3 2 2 100.0% DSI EXO-26 FFM 106 11 10.4% AGA FFM 12 0 0.0% Totals 2989 178 6.0% -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send list subscription requests to `techdiver-request@aquanaut.com'.
Navigate by Author:
[Previous]
[Next]
[Author Search Index]
Navigate by Subject:
[Previous]
[Next]
[Subject Search Index]
[Send Reply] [Send Message with New Topic]
[Search Selection] [Mailing List Home] [Home]