Reply to: RE>>your mail >From memory (apologies if my brain scrambled the message, it has >happened)... one of their points was that by decompressing >on 50% O2, you get many of the benefits of decompressing on pure O2 >(i.e. deco times were pretty close) with a gas that you can use >as deep as 70' and none of the hassles and/or dangers involved >with pure O2. Hmmm... thinking about this assertion. There seems to be a range hovering at about 1.2-1.4 ATA, ppO2 in which O2 toxicity appears. At 50% O2, 79 fsw gives you 1.2 ATA ppO2. What you are proposing, really, is using EAN-50 Nitrox for decompression. I think I would probably be willing to use that mixture starting at, oh, say, 66ft for my decompression, giving me a 1ATA ppO2. (note that I'm not a proponent of Decompression on pure O2 anywhere but at the surface, so perhaps I'm just a bit too cautious). -- Kevin --