At 12.59 96-04-16, John Vanderleest wrote:


--snip--


>The regs are an upstream design (similar to that used in the old twin hose
>regs).

This is not really the case. The Triton servo valve is downstream does open
at 40 bar, but this is way to mutch. (The Jetstream servo is upstream.)

>The overpressure relief value is built into the first stage. This means that
>you can only use the second stage on another brand reg if that reag also has a
>downstream reg attached.
>

Poseidon has a separate overpressure relief valve for sale. If you are
going to use an older (Poseidon) first stage witout a downstream second
stage you shoud use this valve or a jetstream with relief in the hose.

Regards /Sten