Try your local hydraulic shop also, They have viton orings in all sizes and can match them up if given a sample. You wont get the dive shop mark up either. Garrett Weinberg wrote: > Try to get the following o-ring > > 3 - 902 V 894 - 90 > > V refers to Viton > 90 is the durometer > The rest, as best as the o-ring store will tell me is size > > Have used them in multiple Dive Rite manifold rebuilds > > Don't think that McMaster Carr sells this size. Need a specialized company (I > use AOP in Seattle and Portland) > > "Snethkamp,David" wrote: > > > Can somebody give me the proper size and durometer o-ring for the older 200 > > bar isolation manifold. Specifically the two barrel orings found on each > > side of the isolator section. Dive Rite will only tell me they are > > proprietary and will say no more. > > > > David D. Snethkamp > > snethkamp@ne*.rr*.co* <mailto:snethkamp@ne*.rr*.co*>