From: "Ken Sallot" <KEN@co*.ci*.uf*.ed*>
Organization: CIRCA, University of Florida
To: "Michael Fisch (GER)" <100447.2667@co*.co*>, techdiver@terra.net
Date: Fri, 6 Oct 1995 04:15:51 EST
Subject: Re: Regulator adaptation for depths> 100M
> Date sent:      05 Oct 95 14:49:20 EDT
> From:           "Michael Fisch (GER)" <100447.2667@co*.co*>
> To:             "INTERNET:TECHDIVER@TERRA" <TECHDIVER@terra.net>
> Subject:        Regulator adaptation for depths> 100M

> What must be done to adapt 1st. stages when the planned MOD is in excess of
> 100M? Assuming that I will have to crank the intermediate pressure up and
that I
> use higher pressure Intermediate pressure hoses and stronger springs in my 2nd
> stages - what intermediate pressure should I shoot for? Can I then also use
> these regulators at lesser depths?

The intermediate pressure should be between 130-150psi. Just like it 
always is. Remember, the ip (intermediate pressure) is 130-150 OVER 
AMBIENT. So at 100m a gauge checking the IP on your 1st stage should 
still read the same amount.

> BTW I'm paying @ $1.15 per cu ft for helium in Germany, what is the wholesale
> price for helium in the USA? 

I haven't done the math and it's 4am, but I pay $65 for a 330ft3 
bottle.

Ken
--
-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
Ken Sallot                   "There are old divers, and there are bold
CIRCA                         divers, but there are no old bold divers"
(904) 392-2007
kens@uf*.ed*
http://grove.ufl.edu/~ken
-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-