Mailing List Archive

Mailing List: techdiver

Banner Advert

Message Display

From: SRSCHIRATO@BK*.co*.br*
To: trey@ne*.co*, Techdiver@Aquanaut.Com
Subject: RES: DECO
Date: Fri, 15 Feb 2002 11:08:34 -0300
Thanks for your reply. I'm still very curious about your mention in another
post about the different treatment that you give to short deep or long
shallow dives and the way the "curve" doesn't apply to them. Could you
please give me some more information on this?

Thanks again, Sergio

-----Mensagem original-----
De: George Irvine [mailto:girvine@be*.ne*]
Enviada em: quinta-feira, 14 de fevereiro de 2002 22:07
Para: SRSCHIRATO@BK*.co*.br*; Techdiver@Aquanaut.Com
Assunto: RE: DECO


Parameters? Trial and error. I started stopping deeper and shortening the
upper stops until it came out perfect. Those who did not, got bent, one way
or another, from skin bends to pain to muscle bends to just not feeling so
good.

I stopped logging these dives when I crossed 1000 of them, and my team has
logged some 15-20 thousand man dive hours working this out over 10 years.

We document with blood work, doppler , x-ray, scan and vital capacity.

-----Original Message-----
From: SRSCHIRATO@BK*.co*.br* [mailto:SRSCHIRATO@BK*.co*.br*]
Sent: Thursday, February 14, 2002 12:49 PM
To: Techdiver@Aquanaut.Com; girvine@be*.ne*
Subject: RES: DECO


Curiosity: how did you find out the depth for the first stop as being 80% of
the maximum depth? Which were the parameters used?

Thanks, Sergio

-----Mensagem original-----
De: George Irvine [mailto:girvine@be*.ne*]
Enviada em: sábado, 9 de fevereiro de 2002 22:02
Para: Techdiver@Aquanaut.Com
Assunto: DECO




In determining where to start your decompression, the logic is very simple:
you want to let gas escape from the tissues prior to bubbling. Once it
bubbles, it will not escape. Rising up rapidly from depth is a good way to
trap gas in tissues by forming bubbles which will then grow when you are
higher in the water column. On the other hand, gas that bubbles into the
blood is generally trapped by the lungs, but those with any kind of
pulmonary or cardiac shunt are at risk if this occurs. If it occurs to fast
, and or the bubbles grow too large, they can block the effective lung
function and will damage the capillary beds of the lungs. From depth, you
want to remove gas in solution form.

The best way to do this is to begin your decompression stops at 80% of your
profile in atmospheres rounded up . For a ten atmosphere dive, the first
stop is 8 atmospheres, or about 240 feet. At the same time, the travelling
time between 300 and 240 should be at 30 feet per minute max, so ti should
take you two minutes to get to 240.

There is a fine line between getting rid of gas and adding gas at this end
of the deco. All you are trying to do is buy time to get the gas coming out
in solution, and there is a point of diminishing returns for stops in the
lower end of the deco range. The maximum deep stop is 5 minutes, the
minimum is 20 seconds ( 30 FPM ascent) . The best way to assure your ascent
is at the correct speed is to physically stop every ten feet. That will get
you your 20 seconds per ten feet . The range of bottom times that determine
the length of the deep stops is 0-150 minutes. For 0, you still have the 30
foot rate, for 150 minutes you max out at 5 minutes per stop . Anything
beyond this is effective saturation and the maximum applies.

These deep stops are equally divided at all depths up to 65 percent of the
profile. At that point you begin lengthening the stops.  Between 65% and
45% , the steps slightly lengthen, but max out at 10 minutes. Between 45%
and 35%, the max is 20 minutes, between 35 and 25% , the max is 30 minutes,
subject to certain parameters.

Going back to the deepest stop, if you switched gases, and 80% is where you
need to switch gases on a long dive, you are maximizing the effect. If you
use a helium based gas you further improve the results. Air is unacceptable
as a deco gas as it causes damage that can not be fixed by decompressing,
and further complicates the decompression due to the body's immune response
to damage and the stress of rigid red cells jamming through small
capillaries.

When you approach a gas change, you should be coming off of back gas. For
the first deep switch , this is obviously the case. Having been on a low
ppo2 operating gas, you can afford to spike the ppo2 with a deco gas,
whereas yo do not dare do that without breaking to back gas first.  You do
not use a full 1.6 ppo2 fro any part of deep decompression. The risk is too
high. You don't want an oxygen reaction at depth as you will not have any
chance of recovering from this, or surfacing and going back down. Be smart
and rely on helium and gradient more than ppo2 for these steps. Clearly, a
1.4 or less is preferred for deep stops max, whereas shallower you can do
the full 1.6 because you are able to break to a lower effective ppo2
shallow by using back gas. Some people stage a full face mask starting at
these stops. JJ does this.

It takes a solid two minutes for gas to make its first pass through the
body when you switch. The switch step should be the longest of the series
that uses one gas. You are getting the best oxygen window for that gas at
this point, and you just came from a low ppo2, and the gradient is not that
severe. As you move up, the steps do not need to be longer on the same gas.
In fact, you are best served to do your last step before gas switch on back
gas and to make it the shortest of the steps. Here you are relying on
gradient and the toggle effect.

The toggling effect is simply alternating between higher and lower ppo2's
in order to prevent the onset of lung tissue damage , swelling, adding of
protective layers, and constriction of the blood vessels. The reduced ppo2,
especially the closer it gets to normoxic, will prevent and reverse these
effects (other than the damage if it is already done).. Using the gradient
at this juncture is the best way to rid gas.

As you get up into the shallower areas prior to going to oxygen, you should
take a full back gas break - what I call a "cleanup break". For instance,
on a sat dive to 300, I will do 20-30 minutes on back gas at 50 feet.
Cleanup breaks are effectively being done on long dives prior to gas switch
if you do your last step on a gas by going back to the backgas.

In the 40-30 foot range from a deep dive with a long deco, it is
unnecessary to extend the 40 and 30 foot stops at all. In fact these one
can be sharply reduced if you have no shunts. You are better served by
bubbling the gas into the blood stream sat these depths, a far more
efficient and rapid way to get rid of it. Bubbles trapped here can be fixed
by going back down slightly, but doing it just right means that will not
happen to a well perfused diver For instance, on a sat dive to 300 that
would call for 120-140 minutes at 40 feet on any deco program, I do 20
minutes and then move up.

Following each oxygen stint, you must break to back gas. If you were
breathing oxygen dry, as in a habitat or trough, you must do a ten minute
break before going back into the water. The ascent rate from your oxygen
stop to the surface is one foot per minute for a long dive, a scaled down
version of that tor a short dive. The greatest case of bubbling offgassing
occurs in the move from 10 or 20 feet to the surface. You want that to
occur under some pressure and to be controlled by the slow ascent, so that
when you are up, you will not get the sudden rush of bubbles that could
shunt or cause other problems.

For shorter dives, the deco gases are added from the top down. In other
words, your shortest dive might have just oxygen as the only different deco
gas. A longer dive of the same profile may add the 50% gas. Still longer
times would add the 35% gas and so forth. You weigh the advantage of the
gas to the problem of carrying it. The effective shortening of the deco is
not in play here because a shorter dive hits the minimum deco rules, so yo
have to do the time anyway. Longer dives demand the extra gases to stay
efficient. Toggling and alternating are key to decompression. There is no
way you can beat this by maintaining a high ppo2 .



---------------------------------------------------------------------
To unsubscribe, e-mail: quest-unsubscribe@gu*.co*
For additional commands, e-mail: quest-help@gu*.co*


--
Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'.
Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.
--
Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'.
Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.
--
Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'.
Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.

Navigate by Author: [Previous] [Next] [Author Search Index]
Navigate by Subject: [Previous] [Next] [Subject Search Index]

[Send Reply] [Send Message with New Topic]

[Search Selection] [Mailing List Home] [Home]