In a message dated 9/13/2000 4:17:21 PM Eastern Daylight Time, swhac@pc*.gu*.ne* writes: > 1.6 is 1.6 is 1.6 is 1.6 . . . 1.6! These people that you speak of > that have to use 50%, if they use it at 70 feet they are still facing the > same pO2 they would see if they were to use O2 at 20. Things aren't that simple. While the PO2 of 50% at 70 is 1.56, a change in depth to 75 feet ups it to 1.64, a difference of only .08 and not a big deal. The same five foot change in depth on 100% at 20 feet takes the PO2 from 1.61 to 1.76, a much more significant increase of 1.5. A similar statement can be made for 80%. -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.