Mailing List Archive

Mailing List: techdiver

Banner Advert

Message Display

To: adb@he*.re*.or*
Subject: Re: Re: rebreather oxygen treatment
From: Lars_Larsson@in*.se* (Ake Larsson)
Organization: Ineq AB tel: +46(0)418-598 44
Cc: Techdiver@opal.com
Date: 15 Feb 1995 06:11:34 GMT
Hi!

There was a short WENOLL thread a few weeks ago, look in the archives what
was written then.

I have one unit (including manual) and it is a 90% closed rebreather using
standard clinical scrubbers. It is very neatly packed in a small suitcase.
The Wenoll has a (relatively high) constant mass flow of oxygen and therefore
it will vent some gas more or less continously and therefore flush the system
and keep the inert gas fraction reasonably low. I have not yet been able to
do objective testing of the gas fractions in the system with an inertgas load
but will do so during the spring.


Ake Larsson
National Defence Research Establishment
Sweden