Mailing List Archive

Mailing List: techdiver

Banner Advert

Message Display

To: Steve
To: Millard <ec96@li*.ac*.uk*>
Subject: RE:-Oceanic rebreather @ DEMA/Tek'95 ...
From: Chris Hellas <100422.2334@co*.co*>
Cc: Tech
Cc: Diving
Cc: Forum <techdiver@opal.com>
Date: 31 Jan 95 14:11:15 EST
Steve,
              Yes I got lots of photos of the Oceanic unit - cover off and
more!. Most of them are on slide and have yet to be developed. If you are
interested I could s-nail mail them to you when they are done. 

As far as the oceanic rigs go - here is a brief insight  - if anybody has any
further questions I will try and answer them.

Nitrox unit:- 40metre max depth - no decompression unit. The rig will see you
through you first stray into deco and manage you through it. After surfacing it
will lock out until reset at your dealer. Real time software - not configurable
by the end user. Unit uses 2 x 3 litre pony cylinders mounted either side of a 4
hour scrubber stack. Split breathing bags - both back mounted. One inhalation,
one exhalation - either side of the scrubber stack. Hard fibreglass case c/w
neoprene cover.Wrist mounted,hard wired computer display.

Mix unit:- Bread board design completely end user configurable. Can use up to 4
x 3 litre pony cylinders. Can incorporate offboard gas, semi closed bale out,
manual injection etc etc. Full real-time decompression computer. Counter lung &
scrubber set up as per the nitrox unir.

As regards the Biomarine post. The generic Carleton CCR 155 ia available via
Carleton Technologies. Any queries ask Rod Farb - INTERNET:rfarb@em*.us*,edu

Regards

Chris

Navigate by Author: [Previous] [Next] [Author Search Index]
Navigate by Subject: [Previous] [Next] [Subject Search Index]

[Send Reply] [Send Message with New Topic]

[Search Selection] [Mailing List Home] [Home]