Sean, on your point about switching the hose from bc to drysuit, is an optimal hose length hose going to reach? I've never tried this myself, as I consider my lift bag tertiary lift, but has anyone actually successfully done this? Agreed on your points, tho. At 08:23 PM 6/24/1999 -0800, you wrote: >Using only breathable gas in your wings is critical, and should be >reason enough to save argon for the suit. > >Why the second bladder? One bladder for primary buoyancy, drysuit for >backup buoyancy. In the ocean, jettisonable weight belt for tertiary >buoyancy. If you lose the argon, the dive is over, but you can switch >the inflator from your wings to your suit if you need to add gas to >exit. The second bladder and hose just present extra unnecessary >failure points. > >Also, the argon regulator is the only system with no redundant backup. >Using it for your suit only means one hose, and minimum possibility of >failure. > >-Sean > >On Thu, 24 Jun 1999 18:21:53 -0700, jccalvin wrote: > >>Frank, Sean: >> >>I hadn't thought about breathing off the wings. If I lost my Argon supply, >>I have a second bladder connected to my bottom mix. I could inflate the >>wings and then switch the hose to my dry suit, if needed. I was trying to >>save bottom mix but it's probably not worth it. >> >>regards, >> >>John. >> >>-----Original Message----- >>From: Frank Riffel <frank.riffel@en*.co*> >>To: Sean T. Stevenson <ststev@un*.co*> >>Cc: jccalvin <jccalvin@pa*.ne*>; Techdiver@aquanaut.com >><Techdiver@aquanaut.com> >>Date: Thursday, June 24, 1999 12:50 AM >>Subject: Re: Argon Bottle to Wings? >> >> >>>"Sean T. Stevenson" wrote: >>> >>>> Yes. The wing inflator acts as a tertiary (manual addition) backup >>>> regulator. Breathing argon is generally not a good idea. >>>> >>>> -Sean >>>> >>>> On Tue, 22 Jun 1999 16:01:01 -0700, jccalvin wrote: >>>> >>>> >Greetings: >>>> > >>>> >Is there any reason(s) not to connect the Argon bottle to your wings as >>well as to the dry suit? >>>> > >>>> >Thanks, >>>> > >>>> >John. >>>> > >>> >>>Not to forget that when the argon 1st fails (or the bottle is empty) >>>you have lost your entire buoyancy control. >>> >>>Regards, Frank >>> >> >> > > >-- >Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. >Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'. > ----------------------------------------------- Kevin Connell <kevin@nw*.co*> NW Labor Systems, Inc http://www.nwls.com And I suppose you want a user interface with that..... ----------------------------------------------- -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.
Navigate by Author:
[Previous]
[Next]
[Author Search Index]
Navigate by Subject:
[Previous]
[Next]
[Subject Search Index]
[Send Reply] [Send Message with New Topic]
[Search Selection] [Mailing List Home] [Home]