>I'd like to know if anyone can tell me about the oms drysuit inflator >regulator. Does it have an adjustable intermediate pressure and an >overpressure relief system? >Thanx. >Tom O'Connor I bought a few of them last year. The earlier ones had a 300 bar DIN connector while the newer ones came with a 232 bar DIN. I had 6 units, and only 1 of them did not leak from the threads where the DIN screws into the body (not the tank). I had to replace a brass washer in all of them with a teflon washer to stop the leak. The overpressure ports rusted shut after about 9 months, and they never delivered Argon very smoothly. They rattled quite a bit when they wre flowing. I think OMS does not recommend them for use with Argon, so look at their literature. I dumped the OMS and went with a Scubapro MK2 with an overpressure port. -Jon -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.