Date: Sat, 3 Jan 1998 18:49:26 -0800 (PST)
From: Jon Breazile <breazile@ne*.co*>
To: cavekrazi@ju*.co*, cavers@ww*.ge*.co*, techdiver@aquanaut.com
Subject: Re: Dry suit inflator system
>I'd like to know if anyone can tell me about the oms drysuit inflator
>regulator.  Does it have an adjustable intermediate pressure and an
>overpressure relief system?
>Thanx.
>Tom O'Connor

I bought a few of them last year. The earlier ones had a 300 bar DIN connector
while the newer ones came with a 232 bar DIN. I had 6 units, and only 1 of them
did not leak from the threads where the DIN screws into the body (not the tank).
I had to replace a brass washer in all of them with a teflon washer to stop the
leak. The overpressure ports rusted shut after about 9 months, and they never
delivered Argon very smoothly. They rattled quite a bit when they wre flowing.
I think OMS does not recommend them for use with Argon, so look at their
literature.

I dumped the OMS and went with a Scubapro MK2 with an overpressure port.

-Jon
--