Antonio >In the dive number 7, between the minute 17 and 20 the Aladin changes sevaral >times from a decostop (1 minute at >3 meters) to a no decostop (from 8 to 99 minnutes). >Can anybody explain this strange behaviour? Here is my hypothesis: If you look at the tissue loading bars, you will see that certain tissues are still on gassing (red) and others are off gassing (green) during the ascent portion of the dive that you mention. The reason a no stop dive was displayed is that the controlling tissue went below the critical point that required a stop and there were no other tissues that were above this critical point. However, as the ascent continued one of the faster tissues which was still on gassing during the ascent will have gone above the critical point and a deco stop was mandated. Very soon after, this tissue off gassed sufficiently to fall below the critical point and the display reverted to no stop dive. Dave shimell@se*.co* -- Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'. Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.