Mailing List Archive

Mailing List: techdiver

Banner Advert

Message Display

To: techdiver@santec.boston.ma.us
Subject: Re: DCIEM O2 decompression tables
From: gregr@jo*.cs*.su*.OZ*.AU* (Greg Ryan)
Date: Fri, 7 May 1993 16:05:59 +1000
Hans P. Roverud wrote: 

    ... (According to DCIEM oxygen
    is OK at 30 feet, but personally I find no reason to run it that high. I
    actually wrote them 1 year ago and suggested that 20 feet would be a better
    choice. Obviously, DCIEM felt that they had taken a conservative stand
    already, as compared to U.S. Navy standards of oxygen stops at 50 and 40
    feet.)


I posted to this list a week or so ago with my concerns on this point as well.
Wrolf Courtney and David Story (thanks guys!) then informed me that a revised 
table had been published by DCIEM with the O2 stop revised to 3m (20ft).

This revision was made some time between the March 1992 publication and the
last DEMA show.

Does anyone on this list have details on availability of the DCIEM update
package that gives the new tables?

					Greg Ryan	gregr@cs*.su*.oz*.au*

Navigate by Author: [Previous] [Next] [Author Search Index]