EJ,

It is important to consider the absolute partial pressure here not
simply the mole fraction of the gase.  At high ppo2s and long exposures
all sorts of unpleasant physiological things start to happen.

Vasoconstriction  is a natural response of the body to various crises.
Cell damage which releases things like nitric oxide and histamines will
trigger an immune response.  The introduction of snake venom will also
trigger localized vasoconstriction. 

  


E.J. Sadler wrote:
> 
> Although I can't remeber where I read it, and I am trying to locate it, I
> thought that there was some newer research indicating that deco mixes in
> the 85 - 95 percent ranges were actually more efficient in the off gassing
> of inert gasses due to the vasoconstrictive nature of pure O2.
> 
> Does anybody recall hearing about this?
> 
> Or was I just in another nitrogen induced day dream?
> 
> E.J.
> 
> ______________________________
> 
> E.J. Sadler / Particle Studios
> ejsadler@pa*.ne*
> 800.704.3900
> http://particles.net
> ______________________________
> 
> --
> Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'.
> Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.
--
Send mail for the `techdiver' mailing list to `techdiver@aquanaut.com'.
Send subscribe/unsubscribe requests to `techdiver-request@aquanaut.com'.

Navigate by Author: [Previous] [Next] [Author Search Index]
Navigate by Subject: [Previous] [Next] [Subject Search Index]

[Send Reply] [Send Message with New Topic]

[Search Selection] [Mailing List Home] [Home]