Mailing List Archive

Mailing List: techdiver

Banner Advert

Message Display

From: <gmiiii@in*.co*>
Date: Sun, 29 Sep 1996 17:08:30 -0700
Subject: Argon Regulator
To: cavers@ge*.co*, techdiver@terra.net

   I tried the OMS Argon rgulator on a dive at Wakulla this weekend, looking
for 
something to take the place of the Poseidens that are no longer made. The OMS
is 
a similar configuration, with an overpressure relief valve, but without the 
swivel ( one less failure point, and unnecessary). It delivers gas at the 
correct rate (slowly, but enough to keep up with scootering down from zero to 
300, but not fast enough to cause a runaway suit). It is a DIN connection,
which 
I use for everything. It appears to be a wel-made unit, and I see no reason why 
it would not stand up, especially at argon pressures.

   I also tried an OMS steel backplate, looking for a few extra pounds to go 
with the newer DUI insulation, which I also tried at the same time. (This was a 
setup dive, and Sankey and I were superflous on the dive, so could screw it up 
and leave without effecting the outcome). This worked quite well also in 
conjuction with the "v" weight that I use with the OMS 121 tanks to make them 
the same bouyancy as 104's.
 
    The DUI insulation is ridicolous - you might was well be sitting at home as 
diving  - it works that well. I felt no discomfort for an entire 10 hour dive ( 
100 bottom time at 300 followed by 8 hour and twenty minute deco).

George M. Irvine III
DIR WKPP
1400 SE 11 ST Ft Lauderdale, FL 33316
954-493-6655 FAX 6698
Email gmiiii@in*.co*