Yes they did produce a counter lung rather complex equation, however they also ask that it not be published until the new units are out. I would say everyone should get a peek in abiout 3 months. Tom At 09:12 PM 6/13/96 +0000, you wrote: >>To my knowledge no one has measured it. However it is a mute point. You will >>prolong the onset of hypercapnia by using a passive system but it can still >>bite you. > >The interesting thing about the Odyssey which is also true of the BMD, Fenzy >and AGA ACSC ( all volume fraction units ) and is NOT true of the Atlantis I, >Biomarine, or Cis-Lunar is that if the scrubber fails not only will the >FiCO2 rise but the FiO2 will also rise. This will be true for even a partial >scrubber failure. This creates the potential for a double problem ( CO2 and >O2 tox which will act synergistically ). For the BMD and Fenzy it's probably >not a huge problem because you can't dive much past your supply MOD. For the >Odyssey and AGA ACSC you can dive past your supply MOD. > >>The new odessey looks sharp.I'm waiting to pick up my updated system in >>about 4 weeks. > >When will the rest of us get a peek? Did RBC supply you with a counter >lung equation for the Odyssey? > >Barrie > >-- >Send mail for the `techdiver' mailing list to `techdiver@terra.net'. >Send subscription/archive requests to `techdiver-request@terra.net'. >
Navigate by Author:
[Previous]
[Next]
[Author Search Index]
Navigate by Subject:
[Previous]
[Next]
[Subject Search Index]
[Send Reply] [Send Message with New Topic]
[Search Selection] [Mailing List Home] [Home]