Date: Wed, 5 Jun 1996 15:47:39 -0400
From: rnf@sp*.tb*.co* (Rick Fincher)
To: gmiiii@in*.co*, techdiver@terra.net
Subject: Re: O2 Paradox
> From gmiiii@in*.co* Wed Jun  5 14:38:17 1996
> Date: Tue, 4 Jun 1996 18:47:29 -0700
> Cc: techdiver@terra.net
> 
> ...We are 
> getting away with really short decoes by hammering the O2 at 30 in a habitat. 
> When I say getting away, I mean we have nothing that approaches a symptom of 
> DCI...

Can you describe how your habitat is set up? Are you using a medical-type face 
mask or a reg to deliver the O2? Are you surface supplying the O2 or 
pre-positioning tanks in the habitat?

I assume you surface ventilate the habitat so you can take your air breaks by 
just remmoving the mask/reg.

Do you have a procedure in case somebody toxes in the habitat?

Has anybody shown signs of toxing at those pressures and exposure times?

Thanks,

Rick