Mario:

Six points from the poseidon manual

1 defective diaphragm - replace
2 mouth-piece cracked - replace
3 O-ring not fitted or defective - fit or replace
4 foreigen object under exhalation diaphragm -- clean
5 the switch is defective- replace
6 the o-ring under the switch is defective - replace

Ian
you wrote:
>
>Hi scott, 
>     I have replaced the diaphrgam and dove the reg 3 days ago
>with out success, water still comming in. I will check the mouthpiece
>and give it another try.
>Thanks Mario
>
>