On Fri, 1 Dec 1995, Robert Robbins wrote: > One last bit... > It's been pointed out to me that the DSI EXO-26 percent failure (1.4) on my > original posting did not jibe with the data. It should read 10.4. Sorry. Rob: Some questions re your freezing posts: What 1st stage(s) were used with the EXO mask? What do you think about the "exothermic" 2nd stage with regards to freezing? In regards to the poseidon Odin/Thor data, it seems that the unbalanced 1st stage (as found on the cyclon 300 & Thor/Oceanair) is less suceptable to freezing (assuming identical 2nd stages). Is this a "real" effect (your data sets seem large enough to tell). If it is "real," why? My guess would be that the reduced flow of the unbalanced reg (~1000L/min) compared to The balanced reg (~1800 L/min) would lead to less gas cooling upon expansion from the tank to intermediate pressure. thanks, em _____________________________________________________________.sig Eric Maiken email: eapg243@ea*.oa*.uc*.ed* Dept. of Physics o: 714 824-6621 U of California fax: 714 824 2175 Irvine, CA 92715-4575