Mailing List Archive

Mailing List: cavers

Banner Advert

Message Display

From: "Daniel Gault" <djgault@wo*.at*.ne*>
To: "List - Technical Diver" <techdiver@aq*.co*>
Cc: "List - Cave Diver" <cavers@cavers.com>
Subject: Re: uwatec(2)
Date: Tue, 1 Aug 2000 17:24:59 -0400
This is a multi-part message in MIME format.

------=_NextPart_000_0586_01BFFBDD.6B716140
Content-Type: text/plain;
	charset="iso-8859-1"
Content-Transfer-Encoding: quoted-printable

Thanks for all of the helpful responses with information pertaining to =
ascent rates and other button functions.  The other answers were all =
that could be expected and anticipated <g>=20

dg

    -----Original Message-----
    From: Sean T. Stevenson <ststev@un*.co*>
    To: Daniel Gault <djgault@wo*.at*.ne*>; Jess Armantrout =
<armantrout@mc*.co*>; List - Technical Diver =
<techdiver@aq*.co*>
    Cc: List - Cave Diver <cavers@cavers.com>
    Date: Tuesday, August 01, 2000 3:30 PM
    Subject: RE: uwatec
   =20
   =20
    --Original Message Text---
    From: Jess Armantrout
    Date: Tue, 01 Aug 2000 04:18:21 -0500
   =20
    1. Put on wrist.
    2. Get in water.
    3. Repeat steps 1 and 2 above as needed.
   =20
   =20
    -----Original Message-----
    From: Daniel Gault [mailto:djgault@wo*.at*.ne*]
    Sent: Monday, July 31, 2000 3:49 PM
    To: List - Technical Diver
    Cc: List - Cave Diver
    Subject: re: uwatec
   =20
   =20
    I picked up an Uwatec Digital Depth Gauge/Timer at a closeout. If =
anyone has an users manual that they could copy for me I would =
appreciate it. Return info by private e-mail.
   =20
    Thanks
   =20
    dg
   =20
   =20
    Perhaps I can elaborate a bit on Jess' response:
   =20
    Switching on the device
   =20
    Automatically: on submerging in the water
    Manually: by touching the right and top contacts with moistened =
fingers
   =20
    After switching on, all signs of the display light up for =
approximately 5 seconds for testing purposes. Afterwards, a count-down =
of all figures from 9 to 0 starts. After this check, the unit switches =
into ready mode. If no dive is started within the following three =
minutes, the device switches into standby mode automatically (no =
display).
   =20
    Current depth
   =20
    The current depth is displayed in meters (feet). The depth measuring =
is calibrated in meters (feet) fresh water according to international =
standards Therefore in salt water (sea) the display shows a greater =
depth than the actual salt water depth.
   =20
    Maximum Depth
   =20
    Maximum depth of a dive is only displayed if it is greater than the =
current depth (maximum indicator function). To prevent the maximum depth =
from continuously lighting up and going off, the display only appears =
when the current depth is 1 m (or 3 feet) smaller than the maximum depth =
and goes off when the original maximum depth is reached again.
   =20
    Dive Time
   =20
    The Digital indicates the time the diver has spent below 1.2 m (4 =
feet) in minutes. The colon flashes when the clock is running. Maximum =
dive time displayed is 99 minutes. Afterwards, the time measuring =
restarts at zero.
   =20
    Temperature
   =20
    The Digital measures water and air temperature and displays the =
values in C (or F). Beside the value of the temperature, the symbol =
[Temp] appears. It may take a few minutes until the exact temperature is =
displayed, since the sensor for the temperature is located inside the =
housing.
   =20
    Rate of Ascent
   =20
    The ideal rate of ascent varies depending on the depth. The Digital =
measures your rate of ascent and compares it to the programmed target =
values. When ascending, the display of the temperature extinguishes and =
a percentage appears in its place. It indicates the current percentage =
of the target value. Beside, the symbol [Speed] is displayed.
   =20
    Ascent warning
   =20
    100% corresponds to the recommended ascent rate. At 110% an =
additional optical warning in the shape of an arrow appears. Above 140% =
the arrow flashes.
   =20
    Surface Functions
   =20
    Surface Mode
   =20
    After the dive, the diplay [---] appears for 5 minutes. If diving is =
resumed during this period, it is added to the dive just started. After =
this 5 minute period, the dive is completed and entered in the logbook. =
In surface mode, the Digital displays [surface] and the surface =
interval. The surface interval runs untiul another dive is performed or =
until it has reached 24 hours. The Digital then switches into standby =
mode. In surface mode, the Digital also indicates air temperature. If =
there is no operation for 3 minutes, the display extinguishes. However, =
the surface interval keeps on running.
   =20
    Logbook
   =20
    The Digital stores the data of the last 9 dives. A dive is only =
entered if depth was below 1.2 m (4 feet) and the duration longer than 2 =
minutes. On touching the left and right contacts with your fingers after =
switching on or during the surface mode, the mode display [log no.] =
appears. The dive number [1] and maximum depth as well as dive time of =
the last dive are displayed. If the ascent warning [arrow] was displayed =
during the dive for a longer period, it is also entered in the logbook. =
On every subsequent touching of the logbook contacts the previous dive =
to the one currently displayed is called up. After the 9th dive (the =
oldest one), the most recent dive with the number 1 appears again. If =
you keep your fingers permanently on the left and right contacts the =
dives of the logbnook are called up in sequence. If another dive is =
performed, the dive numbers are moved one step backwards and the oldest =
dive up to that moment (no. 9 so far) is deleted. The current or latest =
dive gets the logbook number 1. The nine most recent dives are always =
stored in the logbook. By touching the left and right contacts the =
logbook is closed and the Digital goes back to a state of rest. This =
also occurs automatically if none of the contacts are touched for 3 =
minutes.
   =20
   =20
    Hope this helps.
   =20
    -Sean


------=_NextPart_000_0586_01BFFBDD.6B716140
Content-Type: text/html;
	charset="iso-8859-1"
Content-Transfer-Encoding: quoted-printable

<!DOCTYPE HTML PUBLIC "-//W3C//DTD W3 HTML//EN">
<HTML>
<HEAD>

<META content=3Dtext/html;charset=3Diso-8859-1 =
http-equiv=3DContent-Type>
<META content=3D'"MSHTML 4.72.3110.7"' name=3DGENERATOR>
</HEAD>
<BODY bgColor=3D#ffffff>
<DIV><FONT color=3D#000000 size=3D2>Thanks for all of the helpful =
responses with=20
information pertaining to ascent rates and other button functions.  =
The=20
other answers were all that could be expected and anticipated <g>=20
</FONT></DIV>
<DIV><FONT color=3D#000000 size=3D2></FONT> </DIV>
<DIV><FONT size=3D2>dg</FONT></DIV>
<DIV><FONT size=3D2></FONT> </DIV>
<BLOCKQUOTE=20
style=3D"BORDER-LEFT: #000000 solid 2px; MARGIN-LEFT: 5px; PADDING-LEFT: =
5px">
    <DIV><FONT face=3DArial size=3D2><B>-----Original =
Message-----</B><BR><B>From:=20
    </B>Sean T. Stevenson <<A=20
    =
href=3D"mailto:ststev@un*.co*">ststev@uniserve.com</A>><BR><B>To:=
=20
    </B>Daniel Gault <<A=20
    =
href=3D"mailto:djgault@wo*.at*.ne*">djgault@worldnet.att.net</A>>=
;=20
    Jess Armantrout <<A=20
    =
href=3D"mailto:armantrout@mc*.co*">armantrout@mciworld.com</A>>; =
List=20
    - Technical Diver <<A=20
    =
href=3D"mailto:techdiver@aq*.co*">techdiver@aquanaut.com</A>><BR>=
<B>Cc:=20
    </B>List - Cave Diver <<A=20
    =
href=3D"mailto:cavers@cavers.com">cavers@cavers.com</A>><BR><B>Date:
=20
    </B>Tuesday, August 01, 2000 3:30 PM<BR><B>Subject: </B>RE:=20
    uwatec<BR><BR></DIV></FONT><FONT face=3D"MS Sans Serif"
DEFAULT =3D =
FACE><FONT=20
    size=3D1 DEFAULT =3D SIZE POINTSIZE =3D 8>--Original Message=20
    Text---<BR><B>From:</B> Jess Armantrout<BR><B>Date:</B>
Tue, 01 Aug =
2000=20
    04:18:21 -0500<BR><BR><FONT color=3D#0000ff><FONT
face=3DArial><FONT =
size=3D2=20
    POINTSIZE =3D 10>1. Put on wrist.<FONT color=3D#000000 DEFAULT =3D =
COLOR><FONT=20
    face=3D"MS Sans Serif" DEFAULT =3D FACE><FONT size=3D1 DEFAULT =3D =
SIZE POINTSIZE =3D=20
    8><BR><FONT color=3D#0000ff><FONT face=3DArial><FONT size=3D2 =
POINTSIZE =3D 10>2.=20
    Get in water.<FONT color=3D#000000 DEFAULT =3D COLOR><FONT =
face=3D"MS Sans Serif"=20
    DEFAULT =3D FACE><FONT size=3D1 DEFAULT =3D SIZE POINTSIZE =3D =
8><BR><FONT=20
    color=3D#0000ff><FONT face=3DArial><FONT size=3D2 POINTSIZE =3D =
10>3. Repeat steps 1=20
    and 2 above as needed.<FONT color=3D#000000 DEFAULT =3D COLOR><FONT=20
    face=3D"MS Sans Serif" DEFAULT =3D FACE><FONT size=3D1 DEFAULT =3D =
SIZE POINTSIZE =3D=20
    8><BR><BR><BR><FONT face=3D"Times New Roman"><FONT size=3D2 =
POINTSIZE =3D=20
    10>-----Original Message-----<BR><B>From:</B> Daniel Gault=20
    [mailto:djgault@wo*.at*.ne*]<BR><B>Sent:</B> Monday, July 31, =
2000 3:49=20
    PM<BR><B>To:</B> List - Technical Diver<BR><B>Cc:</B>
List - Cave=20
    Diver<BR><B>Subject:</B> re: uwatec<BR><BR><BR><FONT
face=3D"MS Sans =
Serif"=20
    DEFAULT =3D FACE>I picked up an Uwatec Digital Depth Gauge/Timer at =
a=20
    closeout. If anyone has an users manual that they could copy for me =
I would=20
    appreciate it. Return info by private e-mail.<FONT size=3D1 DEFAULT =
=3D SIZE=20
    POINTSIZE =3D 8><BR><BR><FONT size=3D2 POINTSIZE =3D
10>Thanks<FONT =
size=3D1 DEFAULT=20
    =3D SIZE POINTSIZE =3D 8><BR><BR><FONT size=3D2 POINTSIZE =3D =
10>dg<FONT size=3D1=20
    DEFAULT =3D SIZE POINTSIZE =3D 8><BR><FONT color=3D#000000 DEFAULT =
=3D=20
    COLOR><BR><BR>Perhaps I can elaborate a bit on Jess'=20
    response:<BR><BR>Switching on the device<BR><BR>Automatically:
on =
submerging=20
    in the water<BR>Manually: by touching the right and top contacts =
with=20
    moistened fingers<BR><BR>After switching on, all signs of the =
display light=20
    up for approximately 5 seconds for testing purposes. Afterwards, a=20
    count-down of all figures from 9 to 0 starts. After this check, the =
unit=20
    switches into ready mode. If no dive is started within the following =
three=20
    minutes, the device switches into standby mode automatically (no=20
    display).<BR><BR>Current depth<BR><BR>The current depth is
displayed =
in=20
    meters (feet). The depth measuring is calibrated in meters (feet) =
fresh=20
    water according to international standards Therefore in salt water =
(sea) the=20
    display shows a greater depth than the actual salt water=20
    depth.<BR><BR>Maximum Depth<BR><BR>Maximum depth of a dive is
only =
displayed=20
    if it is greater than the current depth (maximum indicator =
function). To=20
    prevent the maximum depth from continuously lighting up and going =
off, the=20
    display only appears when the current depth is 1 m (or 3 feet) =
smaller than=20
    the maximum depth and goes off when the original maximum depth is =
reached=20
    again.<BR><BR>Dive Time<BR><BR>The Digital indicates the time
the =
diver has=20
    spent below 1.2 m (4 feet) in minutes. The colon flashes when the =
clock is=20
    running. Maximum dive time displayed is 99 minutes. Afterwards, the =
time=20
    measuring restarts at zero.<BR><BR>Temperature<BR><BR>The
Digital =
measures=20
    water and air temperature and displays the values in C (or F). =
Beside the=20
    value of the temperature, the symbol [Temp] appears. It may take a =
few=20
    minutes until the exact temperature is displayed, since the sensor =
for the=20
    temperature is located inside the housing.<BR><BR>Rate of =
Ascent<BR><BR>The=20
    ideal rate of ascent varies depending on the depth. The Digital =
measures=20
    your rate of ascent and compares it to the programmed target values. =
When=20
    ascending, the display of the temperature extinguishes and a =
percentage=20
    appears in its place. It indicates the current percentage of the =
target=20
    value. Beside, the symbol [Speed] is displayed.<BR><BR>Ascent=20
    warning<BR><BR>100% corresponds to the recommended ascent rate. At =
110% an=20
    additional optical warning in the shape of an arrow appears. Above =
140% the=20
    arrow flashes.<BR><BR>Surface Functions<BR><BR>Surface =
Mode<BR><BR>After the=20
    dive, the diplay [---] appears for 5 minutes. If diving is resumed =
during=20
    this period, it is added to the dive just started. After this 5 =
minute=20
    period, the dive is completed and entered in the logbook. In surface =
mode,=20
    the Digital displays [surface] and the surface interval. The surface =

    interval runs untiul another dive is performed or until it has =
reached 24=20
    hours. The Digital then switches into standby mode. In surface mode, =
the=20
    Digital also indicates air temperature. If there is no operation for =
3=20
    minutes, the display extinguishes. However, the surface interval =
keeps on=20
    running.<BR><BR>Logbook<BR><BR>The Digital stores the data of
the =
last 9=20
    dives. A dive is only entered if depth was below 1.2 m (4 feet) and =
the=20
    duration longer than 2 minutes. On touching the left and right =
contacts with=20
    your fingers after switching on or during the surface mode, the mode =
display=20
    [log no.] appears. The dive number [1] and maximum depth as well as =
dive=20
    time of the last dive are displayed. If the ascent warning [arrow] =
was=20
    displayed during the dive for a longer period, it is also entered in =
the=20
    logbook. On every subsequent touching of the logbook contacts the =
previous=20
    dive to the one currently displayed is called up. After the 9th dive =
(the=20
    oldest one), the most recent dive with the number 1 appears again. =
If you=20
    keep your fingers permanently on the left and right contacts the =
dives of=20
    the logbnook are called up in sequence. If another dive is =
performed, the=20
    dive numbers are moved one step backwards and the oldest dive up to =
that=20
    moment (no. 9 so far) is deleted. The current or latest dive gets =
the=20
    logbook number 1. The nine most recent dives are always stored in =
the=20
    logbook. By touching the left and right contacts the logbook is =
closed and=20
    the Digital goes back to a state of rest. This also occurs =
automatically if=20
    none of the contacts are touched for 3 minutes.<BR><FONT =
color=3D#000000=20
    DEFAULT =3D COLOR><BR><BR><FONT color=3D#000000 DEFAULT =3D =
COLOR>Hope this=20
    =
helps.<BR><BR>-Sean<BR></FONT></FONT></FONT></FONT></FON
T></FONT></FONT><=
/FONT></FONT></FONT></FONT></FONT></FONT></FONT></FONT><
/FONT></FONT></FO=
NT></FONT></FONT></FONT></FONT></FONT></FONT></FONT></FO
NT></FONT></FONT>=
</FONT></FONT></FONT></BLOCKQUOTE></BODY></HTML>

------=_NextPart_000_0586_01BFFBDD.6B716140--

Navigate by Author: [Previous] [Next] [Author Search Index]
Navigate by Subject: [Previous] [Next] [Subject Search Index]

[Send Reply] [Send Message with New Topic]

[Search Selection] [Mailing List Home] [Home]